KARA
i
_RM_EN_1-1
w w w . l - a c o u s t i c s . c o m
9
6
INSTALLATION
6.1
Flying a KARAi standalone array
6.1.1
Modeling and safety
Any loudspeaker system must be modeled before installation so as to ensure acoustical and mechanical conformity. This
can be done using L-ACOUSTICS
®
SOUNDVISION Software [3.4] which will assist the user to:
Determine the number of required KARAi enclosures.
Calculate the M-BUMPi site angle and the inter-enclosure angles.
Check the mechanical conformity of the system.
The M-BUMPi can fly an array of up to 12 KARAi enclosures along with all loudspeakers cables (refer to
the KARAi User manual [3.4]). However, this maximum number can decrease in line with the rigging
option [9.1.1] and the array curvature.
Always refer to the mechanical data and warning indications provided in SOUNDVISION software
(Mechanical Data section) to verify the mechanical conformity of the loudspeaker system before
installation.
6.1.2
Array assembling procedure
The following procedure describes how to assemble and fly a vertical KARAi array under an M-BUMPi.
All along the procedure:
Strictly follow the sequence of the successive steps.
Systematically verify that each bolt and screw is fully driven to the torque value given in this manual.
Systematically verify that the bolt is fully driven and locked by a safety pin on each shackle.
Use a strain relief to avoid mechanical stress at the connector locations due to cable weight.
For clarity purposes:
The loudspeaker cabling procedure will not be described.
The loudspeaker cables and the external rigging system will not be represented on the figures.
Required components and tools
M-BUMPi, electric screwdriver with torque selector (N.m or in.lb
f
), T30 Torx
®
bit, 5 mm hex bit, 6 mm hex bit, 10 mm
hex key, 13 mm hex key, KR LOCKBLUE (medium-strength thread-locker, optional, for pullback configuration).
CAUTION
WARNING
WARNING
Summary of Contents for KARAi