KYORITSU KEW2046R Instruction Manual Download Page 1

INSTRUCTION MANUAL

1. Features

 

Designed to meet international safety standards.

IEC61010-1.IEC61010-031 & IEC61010-2-032 

Measurement Category (CAT.) IV 600V

Pollution Degree 2

  

Double  molded  main  body  provides  comfortable 

single handed grip

  

Data Hold Function

  

LCD Backlight function to facilitate working at dimly 

lit situations.

  

REL  function  to  indicate  measurement  variation 

(Current, voltage, Resistance measurement)

  

MIN/MAX  function  enables  easy  reading  of  min  & 

max value during measurement.

  

PEAK  Hold  Function  enables  Peak  value  measure-

ment of starting current. (only at ACA Range)

 

With Continuity & Diode Check Function

 

Capacity measurement of capacitors

  

Temperature  measurement,  switchable  between 

 

and 

  

NCV (Non Contact Voltage) Function for wiring check

  

600V input protection 

  

Sleep Function to extend battery life

  

With Bar Graph, 6039 count display

2. Safety Warnings

This instrument has been designed,manufactured and 

tested  according  to  IEC  61010:  Safety  requirements 

for  Electronic  Measuring  apparatus,  and  delivered  in 

the best condition after passed the inspection.

This  instruction  manual  contains  warnings  and  safety 

rules  which  must  be  observed  by  the  user to  ensure 

safe  operation  of  the  instrument  and  retain  it  in  safe 

condition. 

Therefore,  read  through  these  operating  instructions 

before using the instrument.

#

 WARNING

  

Read  through  and  understand  the  instructions 

contained  in  this  manual  before  using  the 

instrument.

  

Keep the manual at hand to enable quick reference 

whenever necessary.

  

The  instrument  is  to  be  used  only  in  its  intended  

applications.

  

Understand  and  follow  all  the  safety  instructions 

contained in the manual.

  

It  is  essential  that  the  above  instructions  are 

adhered to. 

  

Failure  to  follow  the  above  instructions  may  cause 

injury,  instrument  damage  and/or  damage  to 

equipment under test.

The  symbol 

#

  indicated  on  the  instrument  means 

that  the  user  must  refer  to  the  related  parts  in  the 

manual  for  safe  operation  of  the  instrument.  It  is 

essential  to  read  the  instructions  wherever  the 

#

 

symbol appears in the manual.

#

  

DANGER

  is  reserved  for  conditions  and  actions 

that are likely to cause serious or fatal injury.

#

  

WARNING

 is reserved for conditions and actions 

that can cause serious or fatal injury.

#

  

CAUTION

 is reserved for conditions and actions 

that can cause injury or instrument damage.

  

Marks  listed  in  the  table  below  are  used  on  this 

instrument.

#

User must refer to the manual.

Instrument with double or reinforced insulation
Indicates  that  this  instrument  can  clamp  on 

bare  conductors  when  measuring  a  voltage 

corresponding  to  the  applicable  measurement 

category, which is marked next to this symbol.

AC

DC
AC & DC
This  instrument  satisfies  the  marking 

requirement  defined  in  the  WEEE  Directive. 

This  symbol  indicates  separate  collection  for 

electrical and electronic equipment.

#

 DANGER

  

Never  make  measurement  on  a  circuit  in  which 

voltage over AC600V exists.

  

Do  not  attempt  to  make  measurement  in  the 

presence  of  flammable  gasses.  Otherwise,  the 

use  of  the  instrument  may  cause  sparking,  which 

can lead to an explosion.

  

Transformer jaw tips are designed not to short the 

circuit  under  test.  If  equipment  under  test  has 

exposed  conductive  parts,  however,  extra 

precaution  should  be  taken  to  minimize  the 

possibility of shorting.

  

Never  attempt  to  use  the  instrument  if  its  surface 

or your hand is wet.

  

Do  not  exceed  the  maximum  allowable  input  of 

any measuring range.

  

N e v e r  o p e n  t h e  B a t t e r y  c o v e r  d u r i n g  a 

measurement.

  

The  instrument  is  to  be  used  only  in  its  intended 

applications  or  conditions.  Otherwise,  safety 

functions  equipped  with  the  instrument  doesn't 

work,  and  instrument  damage  or  serious  personal 

injury may be caused.

#

 WARNING

  

Never  attempt  to  make  measurement  if  any 

abnormal  conditions,  such  as  broken  case  and 

exposed metal parts are found on the instrument.

  

Do  not  rotate  the  Function  Switch  while  the  test 

leads are being connected.

  

Do  not  install  substitute  parts  or  make  any 

modification  to  the  instrument.  For  repair  or  re- 

calibration,  return  the  instrument  to  your  local 

distributor from where it was purchased.

  

Do not try to replace the batteries if the surface of 

the instrument is wet.

  

Disconnect  all  the  cords  and  cables  from  the 

object  under  test  and  power  off  the  instrument 

before  opening  the  Battery  Cover  for  Battery 

replacement.

  

Verify  proper  operation  on  a  known  source  before 

use or taking action as a result of the indication of 

the instrument.

#

 CAUTION

  

Set  the  Function  Switch  to  an  appropriate  position 

before starting measurement.

 

Firmly insert the test leads.

  

Disconnect  the  test  leads  from  the  instrument  for 

current measurement.

  

Do  not  expose  the  instrument  to  the  direct  sun, 

high temperature and humidity or dewfall.

  

Altitude  2000m  or  less.

 

Appropriate  operating 

temperature is within 0

 and 40

.

  

This  instrument  isn't  dust  &  water  proofed.  Keep 

away from dust and water.

  

Be  sure  to  power  off  the  instrument  after  use. 

When  the  instrument  will  not  be  in  use  for  a  long 

period,  place  it  in  storage  after  removing  the 

batteries.

  

Use  a  cloth  dipped  in  water  or  neutral  detergent 

for cleaning the instrument. Do not use abrasives 

or solvents.

 

Measurement categories (Over-voltage categories)

To  ensure  safe  operation  of  measuring  instruments, 

IEC61010  establishes  safety  standards  for  various 

electrical  environments,  categorized  as  CAT.

  to 

CAT.

, and called measurement categories. 

Higher-numbered  categories  correspond  to  electrical 

environments  with  greater  momentary  energy,  so  a 

m e a s u r i n g  i n s t r u m e n t  d e s i g n e d  f o r  C AT.

 

environments  can  endure  greater  momentary  energy 

than one designed for CAT.

.

CAT.Ⅰ

:  Secondary electrical circuits connected to an 

AC electrical outlet through a transformer or 

similar device.

CAT.Ⅱ

:  Primary  electrical  circuits  of  equipment 

connected  to  an  AC  electrical  outlet  by  a 

power cord.

CAT.Ⅲ

:  Primary  electrical  circuits  of  the  equipment 

connected directly to the distribution panel, and 

feeders from the distribution panel to outlets.

CAT.Ⅳ

:  The  circuit  from  the  service  drop  to  the 

service  entrance,  and  to  the  power  meter 

and  primary  over  current  protection  device 

(distribution panel).

DIGITAL CLAMP METER

KEW SNAP

 

SERIES

KEW2046R    600A TRMS Type

KEW2056R  1000A TRMS Type

Incoming wire

Interior wiring

Transformer 

CAT.I 

CAT.II

CAT.III 

CAT.IV 

Socket

3. Specification

3-1. Measuring range & accuracy

(accuracy  guaranteed  at  23

±5

,  humidity 

45~85%) AC Current 600A, 1000A Function

Function

Measuring

Range

Accuracy

KEW2046R

KEW2056R

600A

0-600.0A

Peak 1500A

CF=2.5@600A

CF=3.0@500A

±2.0%rdg±5dgt(50/60Hz)
±3.5%rdg±5dgt(40~500Hz)
±5.5%rdg±5dgt(500~1kHz)
* Add 2% at CF>2

1000A

0-1000A

Peak 1500A

CF=2.5@600A

CF=3.0@500A

DC Current 600A, 1000A Function

Function

Measuring

Range

Accuracy

KEW2046R

KEW2056R

600A

0-600.0A

±1.5%rdg±5dgt

±1.5%rdg±5dgt

1000A

0-1000A

AC Voltage Function

(Auto-ranging, Input impedance: approx. 10M

Ω

)

Range

Measuring

Range

Accuracy

KEW2046R

KEW2056R

6/60/600V 0-600.0V

±1.5%rdg±4dgt (50/60Hz)

±3.5%rdg±5dgt (40~400Hz)

DC Voltage Function

(Auto-ranging, Input impedance: approx. 10M

Ω

)

Range

Measuring

Range

Accuracy

KEW2046R

KEW2056R

600mV/6/6

0/600V

0-600.0V

±1.0%rdg±3dgt

Resistance (Diode Check/ Continuity/ Capacity)

Range

Measuring

Range

Accuracy

KEW2046R

KEW2056R

600

Ω

/6k/

60k/600k

Ω

0-600.0V

±1.0%rdg±5dgt

6M/60M

Ω

0.600-60.00M

Ω

±5%rdg±8dgt

Cont Buzzer 0-600.0

Ω

Buzzer sounds at 100

Ω

 or less

Diode

Test voltage: 0-2V

Capacity Function

Range

Measuring

Range

Accuracy

KEW2046R

KEW2056R

40nF

0.01nF

-4000

μ

F

Auto-ranging

the accuracy is not guaranteed

400nF

±2.5%rdg±20dgt

4

μ

F

40

μ

F

400

μ

F

the accuracy is not guaranteed

4000

μ

F

the accuracy is not guaranteed

Frequency/DUTY Function(Auto-ranging for Frequency)

Range

Measuring

Range

Accuracy

KEW2046R

KEW2056R

ACA

40Hz-400Hz

±0.5%rdg±5dgt

ACV

1Hz

10kHz

0.1-99.9%

(Pulse width/Pulse period)

±2.5%rdg±5dgt

Note:  Measurable  inputs  are:  40Vrms@ACV  or 

50Arms@AC600A, 350A@AC1000A Range

Temperature Function

Range

Measuring

Range

Accuracy

KEW2046R

KEW2056R

-50

~     0

±5

±3dgt

0

~  150

±3

±2dgt

150

~  700

±2

±2dgt

-58

~    32

±9

±3dgt

32

~  302

±5

±2dgt

302

~1292

±2%±2dgt

Above  specified  accuracy  is  applied  to  Clamp  meter 

itself. Accuracy of Temperature probe is excluded.

3-2. General Specification

  

Mode of operation 

 

Σ

 mode

  

Display 

: max. 6039 counts 

 (Frequency: 9999, Capacity &Temperature:4039)

& Bar graph

  

Over-range indication  : "OL" displayed when exceeding 

the measuring range. 

 (except for AC/DCV and 1000A Function)

  

Range switching 

 Auto-ranging/Voltage,  Resistance,  Capacity  Range 

Single  range  /  Continuity,  Diode  check,  DUTY  and 

Temperature

  

Sample rate 

: three times per second

  

Functional construction : 

OFF/ ACA/ ACV/ DCA/ DCV/

Ω

  

Keys 

SELECT(AC/DC switching &/

Ω

/   /   /   ), 

PEAK HOLD/ Back Light, REL

 ,Hz/DUTY, MIN/MAX

  

Power source 

: DC3V/ R03(UM-4) x 2pcs

  

Low battery warning  : " 

 " mark is displayed at 

 

  2.4V±0.15V or less.

  

Temperature & humidity  :  23

±5

,  relative  humidity 

accuracy guaranteed  85% or less (no condensation)

  

Operating temperature  : 0~40

, relative humidity 85% 

& humidity range 

  or less (no condensation)

  

Storage temperature  : -20~60

, relative humidity 

& humidity range 

  85% or less (no condensation)

  

Current consumption  : approx. 25 mA

  

Sleep  Function  :  Automatically  powered  off  in  about 

15  min  after  the  last  Function  switch  operation. 

Rotate  the  Function  Switch  from  OFF  to  any 

position to exit from the Sleep state.

  

Applicable Standards

IEC 61010-1 : 2001

Measurement CAT. IV  600V  Pollution degree 2

IEC 61010-031:2002, IEC 61010-2-032

EMC

EN 61326

 EN 55022

 EN 61000-4-2 (performance  criterion B)

 EN 61000-4-3 (performance  criterion B)

  

Overload Protection

Current Range 

:  720A AC/ 10 sec@KEW2046R

 

   1200A AC/DC/ 10 sec@KEW2056R

Voltage Range 

: 720V AC/DC/ 10sec

Resistance Range  : 600V AC/DC/ 10sec

  

Withstand Voltage

6880V AC 

TRMS 50/60Hz

/ 5 sec

(between  Jaws  and  electrical  circuit/  between 

internal circuit and enclosure)

  

Insulation Resistance: 10M

Ω

 or more/ 1000V 

between electrical circuit and enclosure

  

Conductor size

KEW2046R: approx. 33mm

KEW2056R: approx. 40mm

  

Dimension

approx. 254(L)×82(W)×36(D)mm / KEW2056R

approx. 243(L)×77(W)×36(D)mm / KEW2046R

 

Weight : approx 300g @ KEW2046R

310g @ KEW2056R

 

Accessories

Test Leads 

             Model 7066 / 1 set

Battery 

             R03

UM-4

/ 2pcs

Instruction manual  English,  Japanese / 1pce

Carrying Case 

Model 9094 / 1pcs

 

Optional Accessories

    K-type Temperature Probe Model 8216

    Multi-Tran M-8008

 

Effective Value (RMS)

Most 

#

  alternating  currents  and  voltages  are 

expressed  in  effective  values,  which  are  also 

referred  to  as  RMS  (Root-Mean-Square)  values. 

The  effective  value  is  the  square  root  of  the 

average  of  square  of  alternating  current  or  voltage 

values.  Many  clamp  meters  using  a  conventional 

rectifying  circuit  have  "RMS"  scales  for  AC 

measurement.  The  scales  are,  however,  actually 

calibrated  in  terms  of  the  effective  value  of  a  sine 

wave  though  the  clamp  meter  is  responding  to  the 

average  value.  The  calibration  is  done  with  a 

conversion  factor  of  1.111  for  sine  wave,  which  is 

found  by  dividing  the  effective  value  by  the  average 

value. These instruments are therefore in error if the 

input voltage  or current has some other shape than 

sine wave.

  

CF  (Crest  Factor)

  is  found  by  dividing  the  peak 

value by the effective value.

Examples:     Sine wave: CF=1.414

Square wave with a 1: 9 duty ratio: CF=3

3-3. Function Keys

The  "

"  mark  shows  available  function  at  each 

Range.

HOLD PEAK SELECT ZERO Hz/

DUTY

MAX/

MIN

ACA

ACV

-

-

DCA

-

-

DCV

-

-

-

Ω

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

TEMP

-

-

4. Preparation for measurement 

4-1. Checking Battery Voltage

 Set  the  Function  Switch  to  any  position  other  than 

"OFF". When the display is clear without "BATT" mark, 

showing battery voltage is enough. When the display is 

blank or "BATT" mark is indicated, replace the batteries 

according to Section 7, Battery Replacement.

#

 CAUTION

The  Sleep  feature  automatically  powers  the 

instrument off in about 15 min after the last switch or 

key  operation.  Therefore,  the  display  may  be  blank 

even with the Function Switch set to a position other 

than  "OFF".  To  operate  the  instrument  in  this  case, 

turn the switch back to the "OFF" position, then to 

any  other  position.  Replace  the  batteries  if  nothing 

was displayed after above operations.

4-2. Checking Switch Setting & Operation

Confirm  the  Function  Switch  is  set  to  the  correct 

position,the  instrument  is  set  to  the  correct 

measurement  mode,and  the  Data  hold  function  is 

disabled.  Otherwise,desired  measurement  cannot  be 

made. 

Waveform 

Crest factor 

CF 

Average value 

Vavg

Effective value 

Vrms 

Conversion 

factor  

Vrms/ Vavg 

Reading errors for 

average sensing 

instrument 

0.637

1.111

1.414

1.155

1.732

-3.8

×

100

11.1

0.707

2

1

2

2

π

A

3

D

1

3

2

D

1

3

A

0.5A

×

1.111-

3

A

A

A

A

A

1

0.5A

1

0

2 A

π

AD

f

A

A

D

T

2

A

A

×

1,111-A

×

100

×

100

D

A

D

1

A

D

A

1.111

  

-1

D

A

0

A

0

A

0

A
0

T

D=f/T

f

3