Instruction Manual
KEW 2510
DC Milliamp Clamp Logger
www.
.com
[email protected]
1.800.561.8187
Page 1: ...Instruction Manual KEW 2510 DC Milliamp Clamp Logger www com information itm com 1 800 561 8187...
Page 2: ...Other functions 8 7 1 Data Hold function 8 7 2 Auto power off function 8 7 3 Backlight LED light 9 7 4 Analog output function 9 7 5 Memory function 9 8 Communication function Application software 10 9...
Page 3: ...tended applications Understand and follow all the safety instructions contained in the manual It is essential that the above instructions are adhered to Failure to follow the above instructions may ca...
Page 4: ...ver is not securely attached Do not measure AC currents The instrument should be used only in its intended applications or conditions Otherwise safety functions equipped with the instrument do not wor...
Page 5: ...gher numbered categories correspond to electrical environments with greater momentary energy so a measuring instrument designed for CAT III environments can endure greater momentary energy than one de...
Page 6: ...scribedat clause 6 1 100mA 21 0 126 0mA 21 0 120 0mA 1 0 rdg 5dgt Cautions for a long period of measurement or recording About 10 min of warm up is required right after powering on the instrument Temp...
Page 7: ...with Backlight LED light and Bluetooth feature OFF Auto power off Power off function operates in 10 min after the last switch operation This function is disabled when a cord is being connected to the...
Page 8: ...on and get the instrument started If empty battery indicator appears in the LCD replace the batteries with new ones according to 9 Battery replacement in this manual 3 Ensure that the Data hold functi...
Page 9: ...ing the clamp sensor Otherwise accurate results may not be obtained Please open and close the sensor lightly Zero adjustment Perform zero adjustment prior to starting a measurement With the transforme...
Page 10: ...ons Data Hold function This is a function to freeze the measured value on the display Press the Data hold button once to freeze the reading The reading will be held regardless of subsequent variation...
Page 11: ...Store measured values in the internal memory of KEW2510 Hold down the Memory button 1 sec or longer to start recording Another long press will stop the recording The mark keeps blinking on the LCD dur...
Page 12: ...leave the instrument for the warm up period of several tens of minutes after powering it on and then start a recording readings will vary when the ambient temperature changes In this case the tempera...
Page 13: ...an object on the adapter or cord Keep them away from a heating object When disconnecting the adapter from an outlet do so by removing the plug not by pulling the cord How to use AC adapter Remove the...
Page 14: ...inside Replace batteries with new ones when the empty battery mark is displayed on the LCD The LCD does not show anything even the empty battery mark when batteries are completely exhausted How to re...