2H9
1-5-38
(2) Detaching and refitting the power source PWB
Procedure
1. Remove the left cover (See page 1-5-3).
2. Remove the wires from three clamps.
3. Remove five connectors from the power
source PWB.
Figure 1-5-54
4. Unhook four hooks and then remove the
frame left duct.
5. Remove the wire from the clamp.
Figure 1-5-55
YC107
YC104
YC106
YC108
YC105
Clamp
Clamps
Connectors
Power source
PWB
Connectors
Power source
PWB
Frame left duct
Frame left duct
Hook
Hook
Hook
Clamp
Wires
Hook