2F7-2
1-5-26
(2) Detaching and refitting the main PWB
Procedure
1. Remove the top cover (See page P.1-5-2).
2. Remove the right and left cover (See page
3. Remove the six connectors from the main
PWB.
4. Remove the one screw and then remove the
connect-R PWB.
5. Remove the wires from clamp.
Figure 1-5-36
6. Remove the six screws and then remove the
controller box (main PWB).
Figure 1-5-37
Connectors
(six)
Connect
-R
P
WB
Main
P
WB
Screw
Cla
m
p
Screw
Screw
Screw
Screw
Screw
Screw
Controller
box