Kyland Technology (Shanghai) Co., Ltd PTS-30 Time Server
Figure 10 – PTP Setting Screen
Press ‘Save’ button to save the current setting when you change setting.
Items
Parameters
Description
PTP Mode
Master/Slave /Boundary Set PTP working mode.
Delay Measurement
Mode
E2E / P2P / Disable
Set clock delay measurement mode or
disable this function.
Sync Interval
-8~4 / Stop
Set the PTP sync message rate of PTP master
clock. Setting value is n, actual interval is 2
n
seconds. Valid range is from -8 to 4 and Stop.
Default value is Stop.
Delay Measurement
Interval
-8~4 / Stop
Set delay measurement rate. Setting value is
n, actual interval is 2
n
seconds. Valid range is
from -8 to 4 and Stop. Default value is Stop.
Domain1/2
0~3
Set the working domain name for PTP
message.
Priority1/2
0~255
Set working priority for PTP message.
PTP Media
802.3 / IPv4
Set the transmission protocol for
PTP.IEEE802.3 and Ipv4 are supported.
Rx Compensation
0ns
Set the time delay for receiving PTP message.
- 11 -