SICOM6000 User’s Manual 

 

-5- 

Transmission speed: 1.25Gbps (Gigabit), 125Mbps (100M) 

Power supply 

Input  voltage:  12VDC  (9~18VDC),  24VDC  (18~36VDC),  48VDC 
(36~72VDC) 

Input  power  consumption:  <35W  (<47W  equipped  with  fiber 

ports) 

Over‐current Protection: built‐in 

Mechanical parameters 

Physical  dimensions  (height

×

width

×

depth):  165.5mm 

×

320mm 

×

236mm 

Mounting mode: Wall mounting 
Heat  removal  method:  Single‐ribbed  aluminum  case  without 

fans. 

Outlet type: back outlet 

Shell protection class: IP40 
Weight: 5kg 

Ambient conditions 

Operating temperature: ‐40

℃~

85

 

Storage temperature: ‐40

85

 

Humidity: 0

95% (non‐condensing

 

2.2

 

Service

 

Interface

 

1.

 

10/100Base‐TX RJ45 ports. Each RJ45 port has self‐adaptive function, capable of automatically 

configuring  between  10Base‐T  and  100Base‐TX,  between  full  duplex  and  half  duplex  mode, 

supporting MDI/MDI‐X auto‐connection. The transmission distance is less than 100m. 

2.

 

100M  SFP  slots.  100Base‐FX  single  mode  or  multi  mode  fiber  ports.  The  max  throughput  of 

each pair of fiber ports is 100Mbps with compulsory 100M full duplex working mode. Support 

fiber line redundancy technology with recovery time less than 50ms. 

3.

 

10/100/1000Base‐TX  RJ45  ports.  Each  RJ45  port  has  self‐adaptive  function,  capable  of 

automatically configuring between 10/100/1000M, between full duplex and half duplex mode, 
supporting MDI/MDI‐X auto‐connection. The transmission distance is less than 100m. 

4.

 

Gigabit  SFP  slots  supports  hot‐swappable  Gigabit  single  mode  or  multi  mode  fiber  port  SFP   

module  and  RJ45  copper  port  SFP  module.  The  max  throughput  of  each  pair  of  ports  is 

1000Mbps  with  compulsory  1000M  full  duplex  working  mode.  Support  redundancy 
technology with recovery time less than 50ms. 

Summary of Contents for SICOM6000 Series

Page 1: ...SICOM6000 Industrial Ethernet Switch User s Manual KYLAND Technology Co Ltd ...

Page 2: ...ced translated annotated or duplicated in any form or by any means without the prior written permission of KYLAND Corporation Publisher KYLAND Technology CO LTD Address Chongxin Creative Building Shixing East Road 18 Shijingshan District Beijing China Website http www kyland cn Postcode 100041 Tel 8610 88796676 FAX 8610 88796678 E mail sales kyland biz Version V1 March 2010 No 27030058 10 ...

Page 3: ...formance indexes installation and commissioning etc It is a reference for users in system startup expansion and routine maintenance It is also a practical teaching material for user training and technician study This manual mainly includes the following contents Chapter 1 Overview and system features of SICOM6000 Chapter 2 Performance and service functions of SIOCM6000 Chapter 3 Hardware structure...

Page 4: ...s into the equipments 2 Equipment damage or shell breakage 3 Abnormal operation conditions of equipment or the demonstrated performances have changed 4 The equipment emits odor smoke or makes noise z Please keep optical fiber plugs and sockets clean During the operation of equipments do not look directly at the cross section of optical fiber z Please keep the equipment clean if necessary wipe the ...

Page 5: ...SICOM6000 User s Manual Caution attention danger remind the operators places that need to pay attention to ...

Page 6: ...ure 7 3 2 Device Structure 7 3 2 1 Case 7 3 2 2 Base Board 9 3 2 3 Main Control Module 10 3 2 4 Gigabit Interface Module 11 3 2 5 100M Interface Modules 13 3 2 5 1 Interface Module for Fast Ethernet Copper Ports 14 3 2 5 2 Interface Module for Fast Ethernet SFP Slots 15 3 2 5 3 Interface Module for Serial Ports 17 3 2 6 Power Module 18 3 2 7 Blind Plate 22 3 3 Device Application 22 Chapter 4 Hardw...

Page 7: ...ly 30 4 10 Assembly and Commission of SICOM6000 Module 30 4 11 Switch Re installation 31 Chapter 5 Test Methods 32 5 1 Self inspection 32 5 2 TP Port Test 32 5 3 Fiber Port Test 32 Chapter 6 Networking and Configurations 34 6 1 Networking 34 6 2 System configuration 34 Appendix A Twisted pair and Pin Distribution 36 Appendix B Cable Type and Specifications 39 Appendix C Glossary 40 ...

Page 8: ...ucture and IP40 protection class All connectors use industrial products for reliable connection SICOM6000 is designed with full consideration of thermal design reducing vibration design EMC performance etc completely compliant with EMC requirements regulated in IEC61000 Its modular design supports different interface modules not only meeting different service requirements but also convenient for s...

Page 9: ...I etc network management protocols z Supports hardware ACL function providing ACL hardware filtering from L2 L7 z Supports IGMP Snooping detection function z Supports broadcast storm control z Supports full duplex and half duplex mode flow control z Supports rate limitation with the step of n 64K z Reliability MTBF 50000hours MTTR 0 5hour z Supports alarm functions including power alarm IP collisi...

Page 10: ...ace it stably pay attention to the direction of the packing case and ensure its right side is facing upward so as to prevent SICOM6000 falling from the case after opening it If using a hard object to open the case do not over extend the hard object into the case to avoid damage of the equipments inside it After opening the case please check the amount of SICOM6000 equipments according to the packi...

Page 11: ... Quantity of serial ports Max 3 interface modules with 4 RS232 485 serial ports per module System performance Standards IEEE802 3 IEEE 802 3x IEEE 802 3u IEEE 802 3z IEEE 802 3ab IEEE 802 1w IEEE 802 1d IEEE 802 1p IEEE 802 1q IEEE802 3ad forwarding layer 3 switching packets with wire speed Max filtering speed 148810pps 100M 1488100pps 1000M Switching mode Store and Forward Backplane switching cap...

Page 12: ...0Base TX between full duplex and half duplex mode supporting MDI MDI X auto connection The transmission distance is less than 100m 2 100M SFP slots 100Base FX single mode or multi mode fiber ports The max throughput of each pair of fiber ports is 100Mbps with compulsory 100M full duplex working mode Support fiber line redundancy technology with recovery time less than 50ms 3 10 100 1000Base TX RJ4...

Page 13: ...SICOM6000 User s Manual 6 5 Complies with IEEE802 3 802 3u 802 3x 802 3z 802 3ab etc ...

Page 14: ...are made of single ribbed aluminum which are a part of the heat dissipation system The single ribbed structure doubles the heat dissipation area and the heat generated during the unit s working is efficiently dissipated into the air via single ribbed surface with the form of radiation and convection which greatly enhance the high temperature resistance performance of equipment Discard the traditio...

Page 15: ...odule with 8 10 100Base TX RJ45 ports 3 Interface module with 4 RS232 485 serial ports 4 Interface module with 8 100M SFP slots 5 Interface module with 4 combo 1000M SFP slots or 10 100 1000Base TX RJ45 ports 6 Power module 7 Single ribbed panel for heat dissipation 8 Handle 9 Base board 10 Hole to fix base board ...

Page 16: ...6000 is set different interface modules according to actual demand Copper ports and serial ports support RJ45 connector fiber ports adopt SFP slots SICOM6000 supports one power module with power voltage 12VDC 24VDC or 48VDC At two sides are holes for wall mounting and handles The base board structure is shown in Figure 3 3 which indicates the mounting locations for various modules 1 2 3 4 5 6 1 2 ...

Page 17: ...le 5 Slot 4 for Gigabit interface module 6 Slot for power module 3 2 3 Main Control Module The structure of main control module for SICOM6000 industrial Ethernet switch is shown in Figure 3 4 Figure 3 4 Main control module Note 1 POW RUN ALARM L1 L4 indicators in main control module 2 Aligning pin for main control module 1 LEDs in main control module ...

Page 18: ...control module operates abnormally ON System has alarm ALARM OFF System no alarm On Interface modules in slots 1 4 L1 L4 Off No interface modules in slots 1 4 3 2 4 Gigabit Interface Module The structure of Gigabit interface module of SICOM 6000 is shown in the Figure 3 5 Figure 3 5 SICOM6000 s Gigabit interface module Note 1 POW LINK indicators in Gigabit Interface module 2 Gigabit SFP slot ...

Page 19: ...he transmitting port TX in the pair in the same remote switch Using 1000Base LX fiber ports can form redundant fiber ring network with the recovery time less than 50ms which effectively increase the reliability of network operation The SFP modules are shown in the below Figure 3 6 8 7 6 5 4 3 2 1 Copper port Fiber port Gigabit SFP modules hot plug and play steps z Take a close look at SFP module T...

Page 20: ... port ACT Green Off No network activities in the port On Effective network connection in the port LINK Yellow Off No effective network connection in the port 3 2 5 100M Interface Modules SICOM6000 base board provides 3 slots for 100M interface modules supporting 3 kinds of modules interface module for fast Ethernet Copper ports interface module for fast Ethernet SFP slots interface module for seri...

Page 21: ...upporting MDI MDI X auto connection They can be connected to terminal equipments severs hubs or other switches by straight through or cross over cables Each port supports IEEE802 3x self adaptation so the most suitable transmitting mode full half duplex and data transmitting rate 10Mbps 100Mbps can be automatically selected If the devices connected to these ports do not support self adaptation the...

Page 22: ...Ds 2 LEDs per port Blinking Network activities in the port ACT Yellow Off No network activities in the port On Effective network connection in the port LINK Green Off No effective network connection in the port 3 2 5 2 Interface Module for Fast Ethernet SFP Slots Figure 3 9 Interface module for Fast Ethernet SFP slots Note 1 POW LINK indicators in the interface module 2 Fast Ethernet SFP slots ...

Page 23: ...g port TX in the pair in the same remote switch Fiber ports can form redundant fiber ring network with the recovery time less than 50ms which effectively increase the reliability of network operation The structure dimension of 100M SFP modules are the same with Gigabit SFP module 2 LEDs in the interface module Table 3 4 LEDs LED State Description ON 12VDC power input POW OFF NO 12VDC power input o...

Page 24: ...Aligning pin for the interface module 1 Serial ports SICOM6000 serial port module supports 4 channels of serial data with RS232 and RS485 connector but one port supports one type of connector RS232 RS485 The terminal block for serial port is 3 81mm spacing 20 pin phoenix terminal block Its wiring method is the same with power terminal block Wiring sequence is indicated in the following figure ...

Page 25: ...nking Data transmission in serial port T Off No data transmission Blinking Data receiving in serial port R Off No data receiving 3 2 6 Power Module SICOM6000 power module supports dual redundant power inputs and a backup port for failover to improve network reliability It adopts 5 pin 5 08mm phoenix terminal block for power supply The pin definition of input side 1 L 2 N 3 PE 4 N 5 L Power input v...

Page 26: ...terface 5 Grounding hole 6 Aligning pin for power module 1 5 08mm spacing terminal block for power input Use this kind of terminal block to connect power cable according to the power input instruction on product label The section area of power cable is required to be greater than 0 7mm2 and less than 2 5mm2 The cable wiring diagram is as follows ...

Page 27: ...d The cable wiring sequence is shown in the following Figure Setting parameters for hyper terminal port Baud rate 9600 Data bit 8 Parity check None Stop bit 1 Data flow control None Figure 3 14 CONSOLE wiring sequence 3 Terminal block for relay alarm output For the device with single power input it offers power loss alarm for the device with dual redundant power inputs it provides single power inp...

Page 28: ...ternal interface of relay Max Switching Voltage 250VAC 220VDC Max Switching Current 2A Max Switching Power 60W 4 Grounding The power panel of SICOM6000 has a grounding screw hole M4 After crimping one terminal of grounding cable with the cold pressing terminal fix it to the grounding hole with grounding screws The other terminal of grounding cable reliably connects to the ground The section area o...

Page 29: ...t commission The connection status of copper ports are indicated in LEDs in front panel of switch If ports are linked normally their corresponding LEDs will keep on When there are data transmitting and receiving in the ports the corresponding LEDs will blink If RUN indicators blink after electrifying it means the switch work normally And if power indicators keep on it means power module run well P...

Page 30: ...o operate switch to implement network configuration and information query For details see SICOM6000 Series Industrial Ethernet Switch Software User s Manual 5 Switch restart Switch supports software restart and hardware restart Please make the choice according to the actual needs ...

Page 31: ...operating temperature 40 85 Relative humidity non condensing 0 95 3 Earthing resistance 5Ω 4 According to contract requirements check if fiber optical cables are installed in right places and make sure all fiber connectors are appropriate 5 Avoid direct sunshine and keep away from heat source and strong EMI area 6 Check whether there are cables and connectors needed for installation 4 2 Installati...

Page 32: ...10 100Base TX RJ45 ports to connect with terminal equipments by straight through cables and to connect with network devices by cross over cables 2 Connecting power Use the proper power supply voltage listed on the product label After finishing other cables connection connect the power 4 4 Optical Fiber Connection SICOM6000 provides Gigabit SFP slots supporting hot swappable Gigabit single mode or ...

Page 33: ...les to fiber ports 4 After connection check the corresponding LINK ACT indicator in the front panel of switch If the indicator goes on it means an effective connection 4 5 Cable Wiring Cable wiring should meet the following requirements 1 Before cable wiring check whether the specifications models and quantities of all cables comply with the construction drawing design and contract requirements 2 ...

Page 34: ...ount of turnings and avoid turnings with overly small radius Bundle pigtails in proper tightness and avoid too tightly bundling If laid on a cabling rack it should be placed separately from other cables 10 There must be the relevant marks at both ends of cable and the information on the marks should be explicit to facilitate maintenance Attention When laying pigtails prevent optical fiber cable fr...

Page 35: ...k if the cables are connected securely at two ends It is capable of using unused physical ports on the same module to check z Check if the ports at two ends are set at SHUTDOWN mode If they are please delete this configuration z Use serial ports to read port status If the port work normally please change the indicator 4 Switch copper ports works under 100M mode Solution z Check the port configurat...

Page 36: ... serial cable are in good condition If not it means something wrong with serial cable or PC so you need to check them one by one 8 Packet loss in copper ports Solutions z The switches have been strictly tested before they are dispatched from the factory so the probability of packet loss is little But if packet loss happen please check if the connection for copper ports are reliable If it is reliab...

Page 37: ...stalled and connected correctly Don t start up the switch hastily 4 9 SICOM6000 Module Disassembly First cut off the power loosen the screws which are used to fix the switch on the rack pull the switch from the rack place the switch on a smooth table top with foam cushion On the module you are going to replace loosen screws which fix module and base board together pull the module out of the switch...

Page 38: ... work normally install the switch to the rack 4 11 Switch Re installation After the troubleshooting be careful not to leave sundries in the switch gently push the module into the switch in order to avoid damages to the connector in the base board of the switch During the installation of switch take care not to damage the cables After installation ensure easy and smooth sliding in rail During mount...

Page 39: ...If both of them receive complete command without packet loss and the corresponding yellow light of the port keep ON PC work on 100M or keep off PC work on 10M and the corresponding green light blink they mean that these two TP ports are in good conditions Test other TP ports as the same way The PING command example is as follows Figure 5 1 TP port test 5 3 Fiber Port Test As shown in Figure 5 2 fi...

Page 40: ...select the Operation item input cmd WIN2000 or command WIN98 95 and send ping 192 168 100 11 l 1000 t 1 means the number of bytes of sending packets t means keep sending the data Operate the Begin menu on the test computer 2 select the Operation item input cmd WIN2000 or command WIN98 95 and send ping 192 168 100 10 l 1000 t Test computer 1 returns Reply from 192 168 100 11 bytes 1000 time 10ms TT...

Page 41: ...edundant fiber ring network of SICOM6000 6 2 System configuration SICOM6000 industrial Ethernet switch is a modular design with 6 expansion slots one slot for main control module one slot for DC power module one slot for Gigabit interface module and 3 slots for 100M interface modules Required power voltages are 12VDC 24VDC 48VDC Detailed configuration and models are shown in Table 6 1 Table 6 1 Co...

Page 42: ... 4GX GE SFP RJ45 Interface module with 4 combo Gigabit SFP slots or 10 100 1000Base TX RJ45 ports SM6 1 4GX SFP Interface module with 4 Gigabit SFP slots SM6 1 8FE RJ45 Interface module with 8 10 100Base TX RJ45 ports SM6 1 8FX SFP Interface module with 8 100M SFP slots SM6 1 4FX SFP 4FE RJ45 Interface module with 4 100M SFP slots and 4 10 100Base TX RJ45 ports SM6 1 4D 232 485 Interface module wi...

Page 43: ...erting direction is correct 1 8 8 1 Figure A 1 Connector of RJ 45 Pin distribution of 10Base T 100Base TX Unshielded twisted pair UTP or shielded twisted pair STP will be used for the connection of RJ 45 for the connection of 10Mbps category 3 4 and 5 of 100 ohm will be used and cat 5 of 100 ohm will be used for 100Mbps Additionally do make sure that the connecting length of any twisted pair shall...

Page 44: ...a TD 3 Output data TD Receiving data RD 6 Output data TD Receiving data RD 4 5 7 8 Unused Unused Note denoting cable polarity Table A 2 Pin Distribution of 10 100 1000Base TX Pin MDI MDI X single name 1 TD0 2 TD0 3 TD1 4 TD2 5 TD2 6 TD1 7 TD3 8 TD3 Note denoting cable polarity Definition of straight through cable from RJ45 8 pin to RJ45 8 pin Figure A 2 Cable sequence of straight through cable Def...

Page 45: ...SICOM6000 User s Manual 38 Figure A 3 Cable sequence of cross over cable ...

Page 46: ... MMF 5km 1310nm MM SC FC ST 100Base FX 9 125μm core single mode fiber SMF 40km 1310nm SM 80km 1550nm SM SC FC ST 1000Base TX Cat 5 100 ohm UTP 100m RJ 45 1000Base SX 50 125μm multi mode fiber 850nm 500m LC 1000Base SX 62 5 125μm multi mode fiber 850nm 275m LC 1000Base LX 50 125μm multi mode fiber 1310nm 1100m LC 1000Base LX 62 5 125μm multi mode fiber 1310nm 550m LC 1000Base LX 9 125μm single mode...

Page 47: ...tic that is automatically configured to adaptive mode for the speed duplex and traffic control port Bandwidth The information capacity that the channel can transmit For instance the bandwidth of the Fast Ethernet is 100Mbps bit per second Baud Rate It expresses the signaling rate which is defined as the change times of the status for the electric or optical transmission medium within 1 second Brid...

Page 48: ...data packet at the same time Half Duplex The communication for two nodes can only move toward one direction at the same time but cannot move toward both directions MDI It is the Medium Dependent Interface in which one Ethernet port is taken as the receiving terminal to connect to the port of other equipment MDI X Medium Dependent Interface Cross over ...

Reviews: