www.KVS-Klimatechnik.de
E-15
English
12
12 Device Information
1
Type and order code
15MTI
15TTI
20TTI
2
Design
2.1
Degree of protection according to EN 60 529 for compact devices
and heating components
IP 21
IP 21
IP 21
2.2
Installation location
Indoors
Indoors
Indoors
3
Performance data
3.1
Operating temperature limits:
Pool water
°C / °C
+10 to +40
+10 to +40
+10 to +40
Air
°C
-20 to +35
-20 to +35
-20 to +35
3.2
Heat output / COP
at A20 / W24
1
kW / ---
1. This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, other parameters, such as, in particular, defrosting
capacity, bivalence point and regulation, should also be taken into consideration. E.g. A15 / W24 have the following meaning: Heat source temperature 15 °C and heat outlet
temperature 24 °C.
12.35 / 5.12
12.22 / 5.34
20.35 / 4.72
at A15 / W24
kW / ---
11.2 / 4.70
11.2 / 4.93
18.86 / 4.68
at A10 / W24
kW / ---
10.2 / 4.30
10.2 / 4.51
17.25 / 4.30
3.3
Sound power level device / outdoors
dB(A)
55 / 61
55 / 61
57 / 62
3.4
Sound pressure level at a distance of 1 m (indoors)
dB(A)
50
50
52
3.5
Pool water flow with an internal pressure differential of
m³/h / Pa
2.0 / 11100
2.0 / 11100
2.5 / 6760
3.6
Air flow with an external static pressure differential of
m³/h / Pa
4200 / 0
4200 / 0
5200 / 0
m³/h / Pa
2500 / 25
2500 / 25
4000 / 25
3.7
Refrigerant; total filling weight
type / kg
R404A / 2.6
R404A / 2.6
R404A / 4.5
3.8
Lubricant; total filling weight
type / litres
Polyolester / 1.5
Polyolester / 1.5
Polyolester / 1.9
4
Dimensions, connections and weight
4.1
Device dimensions
H x W x L cm
136 x 75 x 85
136 x 75 x 85
157 x 75 x 85
4.2
Device connections to heating system
Inch
Thread 1'' external
Thread 1'' external
Thread 1 1/2'' exter-
nal
4.3
Air duct inlet and outlet (min. internal dimensions)
L x W cm
50 x 50
50 x 50
57 x 57
4.4
Weight of the transportable unit(s) incl. packing
kg
190
190
225
5
Electrical Connection
5.1
Nominal voltage; max. fuse protection
V / A
230 / 25
400 / 16
400 / 20
5.2
A2 W35
kW
3.0
2.82
4.53
5.3
Starting current with soft starter
A
38
23
25
5.4
Nominal current A15 W24 / cos
ϕ
A / ---
11.6 / 0.8
4.6 / 0.8
7.6 / 0.8
6
Complies with the European safety regulations
2
2. See CE declaration of conformity
7
Additional model features
7.1
Defrosting
Automatic
Automatic
Automatic
Type of defrosting
Reverse circulation
Reverse circulation
Reverse circulation
Defrosting tray included
Yes (heated)
Yes (heated)
Yes (heated)
7.2
Heating water in device protected against freezing
Yes
Yes
Yes
7.3
Performance levels
1
1
1
7.4
Controller internal/external
External
External
External