8.2 REQUIREMENTS FIBER CABLES
8.2.1 MULTI-MODE (STANDARD)
A Multi-Mode fiber cable should meet the following requirements:
• Maximum length should be 500 m. The MV1-F includes a fiber Multimode – SFP
Module which allows a transmission distance of up to 500 m.
• Dedicated fiber connection cable type Duplex Multimode 50/125μ (OM3), LC
connector
8.2.2 SINGLE-MODE (OPTIONAL)
A fiber Single-Mode – SFP Module cable should meet the following requirements:
• Up to 20 km transmission distance.
• Requires dedicated fiber connection: cable type Duplex Singlemode with LC connector
A fiber Single-Mode – SFP Module BiDi cable should meet the following requirements:
• Up to 20 km transmission distance.
• Requires dedicated fiber connection: cable type Singlemode with LC connector
Wavelength (λ) of 850 nm in multi-mode or 1310 nm TX -1550 nm RX in single-mode