KVM-TEC KT-6851 Manual Download Page 28

28    |    kvm-tec

Misprints, errors and technical changes reserved

Misprints, errors and technical changes reserved

3. CONFIGURE THE EXTENDER

3.8 USING THE OSD FOR GATEWAY CONNECTIONS

Setup

The Switching Manager that runs in the System requires a xml file, with the Connection data of 
the Virtual Machines. The file should be written manually in the 
“your-SwitchingManager-folder”/api/virtualMachines.xml.

The Data should look like this:

Server is for the IP-Adress so replace the x.

Summary of Contents for KT-6851

Page 1: ...Misprints errors and technical changes reserved gateway Virtual Machines The kvm tec connection to virtual machines MANUAL Gateway Part Nr KT 6851 www kvm tec com...

Page 2: ...switching network A gateway can connect to virtual machines 4 Login credentials can be stored and retrieved by hotkey In addition to your Real Time Switching system the kvm tec gateway can be used to...

Page 3: ...checking the contents 11 1 7 Mounting options 11 1 7 1 Mounting pads and rubber feet 11 2 Installation of the extender 12 2 1 Installing the extender 12 2 2 Quickinstallation Gateway 13 2 3 Operation...

Page 4: ...e RDP connection 27 3 7 Close VNC connection 27 3 8 Using the OSD for Gateway connections 28 4 Maintance Care 30 4 1 Extender care 30 4 2 Disposal 30 5 Warranty 31 5 1 Standard warranty 31 5 2 Extende...

Page 5: ...the product only in the manner as described and for the areas of application as stated When passing the product to a third party be sure to also supply all instructions and other relevant documentati...

Page 6: ...uct DANGER Not for use in potentially explosive environments DANGER Be vigilant at all times and always take care around this product Do not use electrical equipment if you are lacking in concentratio...

Page 7: ...use DANGER Never touch the adapter with wet hands Use the product within the specified performance limits Keep the product away from flammable materials such as curtains and drapes Protect the mains...

Page 8: ...Power supply 12VDC1A external power supply Operation enironment 0 C to 45 C 32 to 113 F Storage environment 25 C to 80 13 to 176 F Relative Luftfeuchtigkeit max 80 non condensing Humidity for storage...

Page 9: ...CTION 1 4 ABOUT THE PRODUCT GATEWAY 1 power status LED display RDP VNC Status 2 DC connection for 12V 1A power supply 3 LAN connection to LAN 4 reset button for reset 5 kvm link connection for CAT X c...

Page 10: ...y Autoupdate Mode fast flashing Update runs shining Update failed shining Update successful Bedeutung LED Anzeigen Color Light display Description shining only network connection available fast flashi...

Page 11: ...t the packaging contains the following content Gateway Local CPU Unit 1 x kvm GW local CPU 1 x wall power supply unit 12 V 1A EU plug or Int plug 4 x rubber feet 1 INTRODUCTION 1 7 MOUNTING OPTIONS 1...

Page 12: ...WARNING Read and understand all safety information before installing the product Easy installation first connect the MX or UVX remote unit then select the RDP or VNC protocol on the KVM gateway Then t...

Page 13: ...ote unit with a network cable 4 connect the screen on the remote side with the DVI cable 5 then connect Remote audio out to speakers or headphones using the audio cable 6 connect the gateway to the In...

Page 14: ...eserved 2 INSTALLATION OF THE EXTENDER 2 3 OPERATION ADDING GENERAL To establish a new connection to a PC you must first press the following button on the main page to add a new connection of your cho...

Page 15: ...sername User name of the PC Password Password of the user Server Server address e g 192 168 0 100 or name of the server Domain Domain name of the RDP server e g RDPTEST Reconnect Disable enable Maximu...

Page 16: ...Now you can enter the following parameters Name Freely selectable name only serves to recognize the user Server Server address e g 192 168 0 100 or name of the server Favoritise Disable enable Used to...

Page 17: ...ECTION First you have to select the saved connection you want to edit on the main page Selected connections are highlighted in blue with white text Once you have selected a connection click the follow...

Page 18: ...TENDER Now you can adjust the connection parameters or switch to a VNC connection The parameters correspond to those found in the Add window When you are done editing save your input by clicking the F...

Page 19: ...NNECTIONS If you have already saved some connections you can filter using the sorting function In order to be able to sort now press on the desired head of a column except Delete after which should be...

Page 20: ...d 2 INSTALLATION OF THE EXTENDER If you click on the Favorites header again the entries will be sorted in descending order 2 8 DELETING A SAVED CONNECTION To do this simply press the trash can button...

Page 21: ...errors and technical changes reserved 2 INSTALLATION OF THE EXTENDER 2 9 QUICK FAVORITING To do this press the star icon of the desired list item and the star will turn yellow or gray yellow Favorite...

Page 22: ...nfo about the currently stored entries The button to connect Connect The option to start the connection in fullscreen mode Fullscreen If you want to use the virtual connection in fullscreen mode activ...

Page 23: ...THE EXTENDER 3 SETTINGS OF THE KVM GATEWAY 3 1 FEATURES The gateway has the following features which can be viewed as a list by pressing the right mouse button 3 2 APPS KVM Client If the KVM client i...

Page 24: ...2 Update Over USB or Over Lan 3 Reboot 4 Preparation Over USB With the feature update Over USB a software update can be performed via a USB stick Please make sure that a connection to a remote partne...

Page 25: ...eech is connected to the Internet Before the update is carried out the entry must be confirmed as follows Update OS With the Update OS feature the installed Gateway operating system can be updated to...

Page 26: ...use wheel rotation you can switch to up to four different desktops Attention Simultaneous access is not possible Preparation If the operating system cannot be updated with Update OS the feature Prepar...

Page 27: ...ction can only be terminated by logging out of the connected PC accessible via the Windows icon in the task bar 3 7 CLOSE VNC CONNECTION To terminate an existing VNC connection proceed as follows By p...

Page 28: ...EWAY CONNECTIONS Setup The Switching Manager that runs in the System requires a xml file with the Connection data of the Virtual Machines The file should be written manually in the your SwitchingManag...

Page 29: ...the virtual machines that you can see are not in use now so feel free to take any of them Once you pressed the enter button the OSD menu will close and a virtual machine should open now Disconnecting...

Page 30: ...ther European countries that operate separate collection systems for waste electrical and electronic equipment By disposing of the product in the proper manner you help to avoid possible hazards for t...

Page 31: ...of purchase The warranty expires in case of External effort improper maintenance Violation of the operating instructions lightning damage Please contact us first before returning the product 5 2 EXTEN...

Page 32: ...Erroneous assignments cannot be found with a simple cable tester The pins for the green pair of wires are not adjacent to one other The cable must at the very least meet the CAT5 specifications and b...

Page 33: ...ager Gateway2Go and API Sharing of videos is realized via the IGMP function of the switch via multicast Each endpoint joins a multicast group even if only one connection is established This process is...

Page 34: ...m tec com Web https www kvm tec com Find our newest updates and FAQs on our homepage https www kvm tec com en support overview support 8 ADDRESS PHONE EMAIL KVM TEC Gewerbepark Mitterfeld 1 A 2523 Tat...

Page 35: ...kvm tec 35 Misprints errors and technical changes reserved 9 NOTES...