Chapter 8: Connecting Power
40
Power cable selection
8.1.2 New Sub-D power connector
(Only applicable for new Sub-D power connector).
The BDU is delivered with a 1.5 m power cable; this can be extended according
to the recommendations below:
The BDU is equipped with an internal 15 A Fuse, therefore no external fuse is
necessary in order to protect the BDU. However, in order to avoid short circuit
in the power cable/connector, the ships DC outlet should be protected by a 15-
20 A fuse or circuit breaker.
Cable Type
Length from source.
Source imp. < 50m
Ω
Length from source.
Source imp. < 100m
Ω
4 mm
2
(AWG11)
0 - 20 m
0 - 15 m
10 mm
2
(AWG8)
a
a. When extending the power cable; positive and negative supply wires must be
installed closely together side by side to keep cable inductance low.
20 - 50 m
15 - 35 m
Make sure that cable
meets inductance
requirements.
a, b
b. Ensure that cable inductance for the selected cable at the desired length is
below the 50
µ
H requirement.
> 50 m
> 35 m
Red: +
Black: -
Summary of Contents for TracPhone F55
Page 22: ...Table of Contents x...
Page 28: ...Chapter 2 GMDSS Installations 6 Power Supply...
Page 40: ...Chapter 3 Placing the Antenna 18 Antenna Mast Design...
Page 48: ...Chapter 5 Installing the BDU 26 Grounding the BDU...
Page 54: ...Chapter 6 F77 Distress Cradle 32 Assembly Alternative...
Page 58: ...Chapter 7 F55 Passive Cradle 36 Passive Cradle Assembly...
Page 64: ...Chapter 8 Connecting Power 42 Power supply specification...
Page 84: ...Chapter 10 Hardware Interfaces 62 Discrete I O interface...
Page 116: ...Appendix C F55 77 BDU Technical Specifications 94 Measuring the Ship Source Impedance...
Page 120: ...Appendix D Distress Cradle Technical Specifications 98 Outline Dimensions...
Page 123: ...Chapter E Passive Cradle Technical Specifications Outline Dimensions 101 EEE...
Page 124: ...Chapter E Passive Cradle Technical Specifications 102 Outline Dimensions...