Chapter 8: Connecting Power
38
Power cable selection
8.1.1 Old 4-port power connector
(Only applicable for old 4-port power connector).
To make sure that the power cable fits the power connector the dimensions of
the cable must be:
•
Cable outer diameter max 3 mm
•
Inner core 1.5 mm
2
The cable inductance should not exceed 5
µ
H. If the inductance is too high,
the power supply may start to oscillate.
To minimize the cable inductance a multi 2- or 4-wire cable should be used.
Recommended power cable types and length:
The power connector has the option of running four cables instead of two,
which allows the cable to be twice as long.
Cable Type
Length from source.
Source imp. < 50 m
Ω
Length from source.
Source imp. < 100 m
Ω
2 x 1.5 mm
2
0 - 10 m
0 - 7 m
2 x 2 x 1. 5mm
2
10 - 20 m
7 - 14 m
Use local AC:DC
converter.
> 20 m
> 14 m
Summary of Contents for TracPhone F55
Page 22: ...Table of Contents x...
Page 28: ...Chapter 2 GMDSS Installations 6 Power Supply...
Page 40: ...Chapter 3 Placing the Antenna 18 Antenna Mast Design...
Page 48: ...Chapter 5 Installing the BDU 26 Grounding the BDU...
Page 54: ...Chapter 6 F77 Distress Cradle 32 Assembly Alternative...
Page 58: ...Chapter 7 F55 Passive Cradle 36 Passive Cradle Assembly...
Page 64: ...Chapter 8 Connecting Power 42 Power supply specification...
Page 84: ...Chapter 10 Hardware Interfaces 62 Discrete I O interface...
Page 116: ...Appendix C F55 77 BDU Technical Specifications 94 Measuring the Ship Source Impedance...
Page 120: ...Appendix D Distress Cradle Technical Specifications 98 Outline Dimensions...
Page 123: ...Chapter E Passive Cradle Technical Specifications Outline Dimensions 101 EEE...
Page 124: ...Chapter E Passive Cradle Technical Specifications 102 Outline Dimensions...