Chapter 2: Installing the system
38
Placing the terminal
2.5.3 Where to place the TracPhone 19” Rack Terminal
Temperature conditions
Ambient temperature range is –25°C to +55°C.
Grounding access
The terminal is designed for installation in a 19” rack. We recommend
grounding the terminal through the rack.
Outline dimensions, 19” Rack Terminal
Note
If you install other equipment close to the terminal in the rack, first
make sure the equipment can withstand the heat that may be
dissipated from the TracPhone 19” Rack Terminal. In max. ambient
temperature the surface of the terminal may reach a temperature
close to 70°C.
Important
The rack for the terminal must be placed in an area where
access to the hull or equivalent grounding can be reached
within 0.5 m.
Summary of Contents for FB250
Page 13: ...Table of contents xii ...
Page 77: ...Chapter 3 Connecting power 64 Connecting power ...
Page 105: ...Chapter 5 Starting up the system 92 Operating the system ...
Page 129: ...Chapter 6 Service and repair 116 Replacing modules in 34 3052B antenna ...
Page 139: ...Chapter 7 Troubleshooting 126 Logging of events ...
Page 165: ...Appendix B Technical specifications 152 TracPhone terminal ...