Removing faults
37
Fault
Cause
Remedy
No data interchange between Tel-
lus and the machine
Check all the cable connections.
Voltage necessary for the unit box
is too low
Check the battery. If "0" display-
ed, check the cables of the con-
nected sensors for a short-circuit.
The voltage necessary for the
electrical system is too low
Check the battery. Replace the fu-
se if the indicator shows "0“.
The voltage necessary for the mo-
tors and hydraulics is too low.
Check the battery. Replace the fu-
se if the indicator shows "0“.
All values have been reset to the
ex-factory setting. Erroneous ent-
ries or errors on the board
Re-enter all inputs for the machi-
ne. If the error occurs again, the
board is defective and must be re-
placed.
Short-circuit in the cable of the
drive motor on the metering de-
vice.
Replace the cable
Drive motor on the metering de-
vice is working too laboriously.
Clean the metering device
Metering device is blocked by a
foreign body
Remove the foreign body
Short-circuit in the cable of the
drive motor on the metering device
Short-circuit in the cable
Drive motor on the metering de-
vice is not connected
Connect the drive motor
The drive motor on the metering
device is turning too quickly or too
slowly
Adapt the drive speed
The metering device is working wi-
th the wrong settings
Check the micrometering setting
The sensor on the metering device
is defective
Replace the sensor
The fan speed is too high or too
low
Keep the fan speed within the tar-
get range
Wrong setting on the metering de-
vice
Check the setting
Seed hopper almost empty
Fill the seed hopper
Calibration test not correct
Perform the calibration test again