28
Operation
Basic settings
Basic settings refer to machine data which is important for controlling
functions or triggering alarms. Basic settings are spread over a num-
ber of pages.
Basic settings Page 1
Symbols
Number of impulses from the travel sensor over 100 metres.
You can determine this value through calibration:
> Exactly measure off 100 metres on the field
> Bring the machine into the operating position
> Activate "Start“ and drive the measured 100 metres
> Activate "Stop“
The number of impulses will be indicated.
> Confirm the value with "OK“
The fan speed can be stored here as a setpoint. To do so, run the fan
at the desired speed. The actual value is displayed in blue in the cen-
tre.
> Once the value is reached, store it with "SET".
The bottom and top limits for an alarm are then calculated automati-
cally.
Enter the desired percentage steps for increasing and decreasing the
sowing amounts. The sowing quantity is increased or decreased in the
information screen using the appropriate keys.
→
Fan speed. Store the value with "SET".
Increased or reduced quantity
Number of impulses/100 m. Start recalibration with "START"
Number of metering devices
Working width of the machine in metres
Number of shares
Only active if the GPS connection has been selected (Task Control)
m = distance from GPS aerial to the rear, middle share
s = time required by seed from metering device to share
m