62
Troubleshooting
Troubleshooting IsoMatch Grip
Failure
Possible cause
Solution
Connected implement does
not appear in the Implement
Selection.
Implement is not properly connected.
Check cable connections.
Implement is not ISOBUS compatible.
Check ISOBUS compati-
bility of the implement.
Alarm warning: UT version 3
or higher is required.
No UT version 3 or higher is found.
Check with the help of
the
Presetting screen
the UT version (not se-
lectable on IsoMatch Tel-
lus GO and PRO).
Reboot the terminal after
changing UT version.
Alarm warning: No UT in-
stance 1 (0) found.
UT instance 1 (0) is required.
Check with the help of
the
Presetting screen
the UT instance.
Reboot the terminal after
changing UT instance.