Adjustments
98
Procedure
Seed drill preparation
Unscrew the two knobs (A) located on
the distribution sheet (B).
Re-install the lower plate (C) to accentuate its slope.
Attach the lower plate in position on the frame using the knob (D)
located to the right.
Place a bag or recipient at the extremity of the distribution sheet to
recover the seeds.
Adjustments
In the main menu, select the "Flow test" tab (1).
Enter the working width (2).
Enter the average travel speed (3) that you wish to work at.
Enter the quantity of seed (4) that you wish to sow.
Enter the duration of the distribution test (5).
If all values are correctly adjusted, launch the test (6).
The test starts (7).
•
The rotor turns automatically without the blower.
•
At the end of the defined time, the rotor stops automatically.
•
On 500 L seed drills, or if a hopper level sensor is mounted, the
message "Recipient almost empty" may appear, but the test will
still carry on. The lack of seeds may however lead to an inexact
test.
If required, press on XX or XX to interrupt the test.
1
2
Tractor -
speed ?
3
4
Calibration
time ?
0.5 min
Calibration testing !
5
6
7
A
B
C
D
Distribution time
Example
Default
1 minute
Small seeds
2 minutes
Rapeseed, phacelia, poppy
Large seeds
30 seconds
Wheat, barley, peas
Summary of Contents for a-drill
Page 80: ...Seed drill adjustment 80 Sowing tables ...
Page 81: ...Seed drill adjustment 81 ...
Page 82: ...Seed drill adjustment 82 ...
Page 83: ...Seed drill adjustment 83 ...
Page 84: ...Seed drill adjustment 84 ...
Page 85: ...Seed drill adjustment 85 ...
Page 89: ...Filling the seedbox 89 Qualidisc and Qualidisc Farmer Unfold the machine Fill in the seedbox ...
Page 95: ...Adjustments 95 Main display Organisation of the menus ...