Delivery and assembly
55
Folding machines
End of Field sensor (A)
The end of field sensor stops distribution when you raise the machine
to turn. Distribution automatically restarts when you lower the
machine.
Install the end of field sensor on the machine upper link coupling.
Attach the support using 2 M8 bolts.
Adjust the sensor position so that the tractor upper link activates
the sensor when the machine is raised.
Radar sensor (B)
The radar system allows you to adapt the seed distribution flow to your
tractor speed.
Install the radar support on the reinforcement plate located under
the front beam of the frame.
Fix the support using 4 M8x16 bolts.
Install the radar on the support.
Fix the radar using 4 M8x16 bolts.
Rigid and folding
machines
Tractor speed information cable
The rotor distribution speed can also be communicated to the control
box via a 7 terminal cable. However, your tractor must be equipped
with a 7-terminal speed information socket.
A
B
Never look directly at the radar detection head when
operating.
This could cause serious eye injuries.
A
12-pin socket (control box)
B
7-pin socket (tractor)
A
B