background image

Kvaser T-Cannector Expansion L User’s Guide

Copyright 2021-2021 Kvaser AB, Mölndal, Sweden
https://www.kvaser.com

Printed Monday 13

th

September, 2021

We believe that the information contained herein was accurate in all respects at the time of printing.
Kvaser AB cannot, however, assume any responsibility for errors or omissions in this text. Also note
that the information in this document is subject to change without notice and should not be construed
as a commitment by Kvaser AB.

Summary of Contents for T-Cannector Expansion L

Page 1: ...er 2021 We believe that the information contained herein was accurate in all respects at the time of printing Kvaser AB cannot however assume any responsibility for errors or omissions in this text Also note that the information in this document is subject to change without notice and should not be construed as a commitment by Kvaser AB ...

Page 2: ...Kvaser T Cannector Expansion L User s Guide 2 18 This page is intentionally left blank Kvaser AB Mölndal Sweden www kvaser com ...

Page 3: ...Base unit hardware 7 3 1 Power Distribution 8 3 2 LED Indicators 8 3 3 Termination Adjustment 9 4 Kvaser T cannector L Extension unit hardware 10 4 1 Assembly 12 5 Appendices 13 5 1 Technical data 13 6 Disposal and Recycling Information 14 7 Legal acknowledgements 15 7 1 Usage warning 15 7 2 EU Regulatory Compliance 16 8 Document Revision History 18 Kvaser AB Mölndal Sweden www kvaser com ...

Page 4: ... L User s Guide 4 18 1 About this manual This manual is intended for Kvaser T Cannector Expansion L users This document contains a description of the hardware s properties and functionality Kvaser AB Mölndal Sweden www kvaser com ...

Page 5: ...ers eight D SUB9 socket connectors An adjustable CAN termination load connecting an optional resistor of 120 Ω or 60 Ω is provided by the Kvaser T cannector v2 Base unit and thus provides an affordable and safe way of terminating the CAN bus when using Kvaser interfaces on a development board When attached and powered via the Kvaser T cannector v2 the CAN bus hub is also capable of powering bus po...

Page 6: ...extension to the Kvaser T cannector v2 00776 5 Extends the Kvaser T cannector v2 to in total eight D SUB9 socket connectors Adjustable termination via easy to use three way switch Base unit LED to indicate power on Base unit Voltage range of 12 24 V DC Kvaser AB Mölndal Sweden www kvaser com ...

Page 7: ...B9 plug connector see Figure 4 on Page 8 Figure 3 Pinout of D SUB9 socket All pins of these connectors are fully connected e g pin 1 on each connector is connected to pin 1 on all other connectors see Figure 5 on Page 8 Pin 9 V and pin 3 GND are connected to the power supply A power indicator LED is connected as shown in Figure 5 on Page 8 The termination resistor is selectable using the three way...

Page 8: ...unit 3 1 Power Distribution The Kvaser T cannector v2 Base unit may be powered from an external DC power supply via a 2 1 x 5 5 mm connector providing a power source for Kvaser CAN interfaces The Kvaser T cannector v2 Base unit may also distribute power via V in any of the D SUB9 connectors 3 2 LED Indicators The Kvaser T cannector v2 Base unit has one red power LED indicator see Figure 6 on Page ...

Page 9: ...cannector v2 Base unit 3 3 Termination Adjustment The Kvaser T cannector v2 Base unit has an adjustable CAN termination that provides an effective way of terminating the CAN circuit The optional termination of 120 Ω or 60 Ω is selected through a three way switch see Figure 6 Kvaser AB Mölndal Sweden www kvaser com ...

Page 10: ...aser T cannector L Extension unit is a CAN bus hub with three plus one D SUB9 sockets see Figure 10 on Page 11 and one D SUB9 plug connector see Figure 11 on Page 11 designed for connecting to a Kvaser T cannector v2 Base unit All pins of the D SUB9 connectors are fully connected e g pin 1 on each connector is connected to pin 1 on all other connectors see Figure 9 on Page 11 Kvaser AB Mölndal Swe...

Page 11: ...de 11 18 SHIELD V AUX 4 AUX 3 GND CAN H CAN L AUX 2 AUX 1 P1 P2 P3 P4 P5 Figure 9 Schematic over the Kvaser T cannector L Extension unit Figure 10 Pinout of D SUB9 socket Figure 11 Pinout of D SUB9 plug Kvaser AB Mölndal Sweden www kvaser com ...

Page 12: ...ected on top of the Kvaser T cannector v2 Base unit The final step is to connect the assembled Kvaser T Cannector Expansion L to a Kvaser T cannector v2 00776 5 as shown in Figure 13 The difference between the Kvaser T cannector v2 Base unit and the Kvaser T cannector v2 is that the former has the hex nuts on the D SUB9 plug exchanged to screws in order to facilitate fastening of the assembly This...

Page 13: ...ht 100 g Operating temperature 30 C to 80 C Storage temperature 40 C to 85 C Relative humidity 0 to 85 non condensing Table 2 Technical Specifications for Kvaser T cannector v2 Base unit In Table 3 below you will find the Kvaser T cannector L Extension unit s technical specifications CAN Connectors 3 1 sockets 1 plug D SUB9 Galvanic isolation No CAN Bit Rate 1 Mbit s Classic CAN CAN FD Bit Rate Up...

Page 14: ...formation When this product reaches its end of life please dispose of it according to your local environmental laws and guidelines For information about Kvaser s recycling programs visit https www kvaser com en kvaser recycling policy html Kvaser AB Mölndal Sweden www kvaser com ...

Page 15: ...USE DAMAGE TO EQUIPMENT DEVICES OR THE SURROUNDING ENVIRONMENT WITH THIS DEVICE YOU MAY POTENTIALLY CAUSE A CHANGE IN THE OPERATION OF THE SYSTEM MODULE DEVICE CIRCUIT OR OUTPUT TURN ON OR ACTIVATE A MODULE DEVICE CIRCUIT OUTPUT OR FUNCTION TURN OFF OR DEACTIVATE A MODULE DEVICE CIRCUIT OUTPUT OR FUNCTION INHIBIT TURN OFF OR DEACTIVATE NORMAL OPERATION MODIFY THE BEHAVIOR OF A DISTRIBUTED PRODUCT ...

Page 16: ...r v2 Object of the declaration identification of apparatus allowing traceability Product Kvaser T cannector v2 Type 73 30130 00776 5 The object of the declaration described above is in conformity with the relevant Union harmonisation legislation RoHS recast Directive 2011 65 EU Art 4 1 The following harmonised standards and technical specifications have been applied title date of standard specific...

Page 17: ...the declaration identification of apparatus allowing traceability Product Kvaser T Cannector Expansion L Type 73 30130 01203 5 The object of the declaration described above is in conformity with the relevant Union harmonisation legislation RoHS recast Directive 2011 65 EU Art 4 1 The following harmonised standards and technical specifications have been applied title date of standard specification ...

Page 18: ...nector Expansion L User s Guide 18 18 8 Document Revision History Version history for document UG_98236_t cannector_v2_l Revision Date Changes 1 0 2021 09 07 Initial version Kvaser AB Mölndal Sweden www kvaser com ...