RDS300/RDS500/RDS1000 User Manual 3.10
recommendation. It will be necessary to use MEC 2D to transmit relevant information to the
encoder.
Any ASCII(text) command can be coded in UECP and can be sent to the encoder. So in order
to configure the PS scroll or Dynamic PS scroll please refer the chapter B to know the exact
command to code.
For example In order to configure PS_text command (see chapter B) the
following MEC 2D should be used:
2D MEC
02-FD MEL
41 Manufacturer designation (K)
5A Manufacturer designation (V)
50 P
53 S
5F _
54 T
45 E
58 X
54 T
3D =
Etc…
Of course this message must be include in a valid UECP frame.
B. ASCII configuration.
The RDS Encoder enables to be configured with simple terminal software. The terminal must
be set up with the following parameters for the PC communication port.
Baud rate :
9600 Bps
Data Bits:
8
Parity:
None
Stop bit:
1
Flow control:
None
Once the terminal is correctly configured, switch on the encoder to display the equipment
auto test.
STATIC PS configuration with CONSOLE mode
The command to set up the Static PS name of the active PSN is
PS=……..
The “PS=” command value is stored in a EEPROM i.e.
PS=Radio 1 will display Radio 1 on your receiver.
PS?
Returns the configured static PS name
PS scroll configuration with CONSOLE mode
The command to set up the PS SCROLL is
PS_SCROLL= a,b,c,d,<text>
The “PS_SCROLL=” command value is stored in a RAM