72,000 Cycle Maintenance Steps
KVAL Service Manual
3-12
72,000 Cycle Maintenance Steps
Follow Lockout Tagout procedures,
Inspect Nuts and Bolts
Inspect all nuts and bolts for tightnesses Tighten is necessary. Use appropriate tool to
verify that the hardware is tight.
Check Door Feeding Transition (If Applicable)
Electrical
Check all connections in each node box and electrical panel. Wires may become loose due to
vibration. Check contactors for wear.
Computer Backup
Backup computer software.
Wash Filter and Lubricator Bowls
Check that there is a smooth transition
with a door feeding into and out of
machine.
Feed door in and out to verify smooth tran-
sition is repeatable.
Wash filter and lubricator bowls with
soapy water.
• Slide lock down to
unlock.
• Twist bowl to remove it.
• Remove filter from Air
filter assembly. Inspect
and clean or replace if
necessary.
• Clean bowls and reas-
semble.