Start Light OFF
If the Start light remains unlit, push in the Start button
and hold it in while a second person checks for volt-
age between #2 and #5. If there is 120 VAC, replace
the ACR relay. If there is no voltage while the button
is held in, check the wiring or the contact on the
Start
button.
Troubleshooting with the Status Light Panel
4-11
KVAL DL-2 Series Operation/Service Manual