About the Electrical Panels
2-9
KVAL Acro-HD Operation/Service Manual
About the Electrical Panels
The Acro-HD has a Main Electrical Panel. This section is an overview of the electrical compo-
nents. Refer the machine's electrical prints for in-depth information.
The Main Electrical Panel:
• Supplies voltages to the machine
• Contains the PLC (Programmable
Logic Controller)
• Contains tilt motor and table motor
overload relay circuits.
• Contains the foot pedal terminals
• Contains fuses.
• Contains a 24VDC
Warning:
High Voltage is present in this panel at the top of the Three Phase
Input
even with the disconnect off
. If working on the panel, follow safety pro-
tocol as described in Chapter 1.
Main Electrical Panel
ACR
PLC
24VDC Power
Supply
120Vac and 24VDC
Terminal
Fuses
Tilt Motor
Overload
Relay
24VDC Relays
High Voltage
Input
Disconnect
Control Transformer
Table Motor
Overload
Relay
Foot Pedal Terminal