Calibration of the Back Section
3-17
KVAL 994-X Operation Manual
Calibration of the Back Section
For the
994-X
, there are two screens available to calibrate the back section. To calibrate, follow the
directions in
“Enter a Positive or Negative Number?” on page 3-7
At the
Main Screen
select
Setup
-->
Main Cal
to get to the Machine Calibration screen to access:
• Lock Location Calibration
• Lock Bore Location r
:t
FIGURE 3-10.
Path to Calibration screen Back Section
Lock Location Calibration
FIGURE 3-11.
Reference Door Lock
To start, run a known good lock cut at a standard location on
a Right Hand or Left Hand door.
Once the lock cut is completed, check the distance from the
top of the door to the center of the lock.
Note the measurement value and compare to specification
If the lock location is correct, there is no need to perform
this process, If it is not correct, follow the instructions in See “Adjusting
Measure