Lubrication Requirements
KVAL 990-H Service Manual
3-18
Lubrication Requirements
This section describes the parts of the machine that require periodic lubrication, and specifies the
lubricants. In addition, it explains how to maintain the lubrication systems on the machine.
Linear Bearings, Flange Bearing, and Pillow Blocks
If the bearing is equipped with a grease fitting (Zerk Fitting), it should receive 1 Gram (one pump
from grease gun) of Dura-Lith Grease (KVAL P/N Lube EP-2) every 250 hours of operation.
Note:
Bearings without grease fittings have been pre-lubricated at the factory and do
not require further lubrication.
Zerk Fittings
Zerk Fitting Location
Depends on Position of
Slide
FIGURE 3. 7.
Zerk Fittings