600 Cycle Maintenance Steps
3-5
KVAL 990-F4 Service Manual
600 Cycle Maintenance Steps
Follow Lockout Tagout procedures,
see “Lockout Tagout Procedure” on page 1-11
Check Air Gauges and Inspect Water Traps
Inspect Tooling
Air Pressure Gages. Adjust, if nec
-
essary, to the proper PSI located on
the label.
(Adjust only if Trained
in Maintenance)
Inspect Air Filter Water Traps.
Empty trap if necessary
Slide locking switch down to
unlock twist trap to remove.
Reverse action when installing
trap.
Inspect the Tooling for wear, (Drill Bits, Cutting Tools, Screw Driver Bits)
See “Replacing Tooling in the Front Section” on page 3-33 and see “Replacing Tooling in the