About the Machine Sensors
4-21
KVAL 990-F4 Service Manual
About the Machine Sensors
If issues point to the sensors, use a DVM (Digital Volt Meter) at the PLC to check the voltages in
the “On” and “Off” states. Measure the voltages at the inputs at the PLC terminals. See the
machine drawing for detailed wiring connections.
Sensor Locations
The Figures show the sensor locations on the machine. (
990-F4
is displayed)
.
Auto Adjust
Edge Sense Eye
Before In-
Feed Stop Eye
After In-Feed
Stop Eye
Door In
Machine Eye
Before Out-
Feed Stop Eye
After Out-Feed
Stop Eye
Width Adjust
Inside Eye
Width Adjust
Outside Eye
X-Axis
Reverse Limit
X-Axis
Home
Limit
X-Axis For
-
ward Limit
Open Width
Adjust Safety
(Limit Switch)
Close Width
Adjust Safety
Head #1
Six
Shooter
Back Section
Front Section
Head #2
Head #3
Head #4