About Calibration
3-2
965X Operation Manual
Calibration is all about the confidence in the end results of your manufacturing process. Calibra
-
tion assures you that your cut parameters are accurate and within the specified limits.
If slight discrepancies in the machining of a jamb are observed, the built in
KvalCAM
calibration
can adjust the tooling to fix the issue.
In troubleshooting, calibration can be an essential step in solving the issue.
About the Calibration Menus and the Calibration Reference Cut
This chapter describes the
Calibration Menus
.
In the
Calibration Menus
, offsets are entered to calibrate assemblies in the machine.
See “About
the Calibration Tabs” on page 3-3.
Before you Calibrate
Before you start calibration, check for the following common issues.
1.
Is the loaded setup correct for the current cut?
2.
Check tools for wear.
3.
Is the correct Calibration loaded?
4.
Are the stops set up correctly?
5.
When did the problem first start? during a run, at start up.
6.
When was the last calibration?
7.
Is the jamb True?
8.
Check for sawdust build-up, which may affect depth.
Note: Kval
recommends that a test jamb is run first and checked for specifications
before a full run is started.
Summary of Contents for 965X