System IT Administration
3-2
KVAL 558 Operation Manual
System IT Administration
For optimum support, the 558 requires internet access. With internet access, KVAL Service Sup-
port will be able to access your machine through your company’s intranet and help solve any
issues that may occur. Connection to the intranet is achieved by interfacing with the 558 control-
ler. The location of the intranet connection is identified in the figure below (RJ45 to intranet.)
About the 558 Computer
The 558 uses a Beckhoff
®
CPU module as a PLC (Programmable Logic Controller.) In addition
to the CPU and the chipset, the module also contains internal main memory. The computer has a
removable Compact Flash card from which it boots.The controller uses a Windows CE
®
operat-
ing system with TwinCAT 2
®
automation software to create the PLC and Motion Control method.
Interface modules include:
• A smart power supply to connect to EtherCat
®
terminals. This supply contains a
LCD to display system and user messages.
• A DVI/USB module to connect to the user interface.
• An Ethernet module to connect to the servo amplifiers.
Connections on the PLC
The CPU module is located in the upper left corner of the Electrical Panel. See “Identification of
Electrical Panel Parts” on page 2-9.
Smart Power Supply and EtherCat
Ethernet Module
to Servo Amp
DVI/USB Module
to User Interface
CPU Module
RJ45 to
Intranet
Compact
Flash Card
Battery
Summary of Contents for 558
Page 4: ...KVAL 558 Operations Manual ...
Page 24: ...Safety Sign Off Sheet 1 18 KVAL 558 Operation Manual ...
Page 51: ...Description of User Interface Screens 2 27 KVAL 558 Operation Manual ...
Page 58: ...Description of User Interface Screens 2 34 KVAL 558 Operation Manual ...
Page 62: ...System IT Administration 3 4 KVAL 558 Operation Manual ...
Page 66: ...Notes ...
Page 67: ...Notes ...