AUTO CURRENT
D.C. CURRENT SENSOR
INSTALLATION INSTRUCTIONS
TEL: in NY 631-567-0314 TOLL FREE: 800-346-0857 FAX: 631-567-5826
KUSSMAUL ELECTRONICS CO., INC.
170 CHERRY AVE., WEST SAYVILLE, N.Y. 11796
SCHEMATIC
The Auto Current detects current and closes a
switch when the sensed current flows, to provide a
remote indication. Designed for applications where
a remote indicator must be illuminated when one or
more lights or other loads are energized. By detect-
ing load current any one, or more than one lamp, or
other load will cause the indicator to light. The
indicator circuit contains a relay which is operated
by the sensor, indicator currents as high as 5 am-
peres may be driven by relay.
Chassis
Ground
Chassis
Ground
Chassis
Ground
Chassis
Ground
Chassis
Ground
Door
Switch
Door
Switch
Compartment
Lights
Loads
Loads
Indicator
Lamp
Fuse
S1
S2
12V
IND
GND
MODEL
NUMBER
ORDERING INFORMATION
RESIST
OHMS
MIN. OPER.
AMPS
MAX. OPER.
AMPS
SWITCH
RATING 12V
091-22-2
091-22-3
091-22-5
.01
.01
.02
1.0
.5
.25
30
30
10
5 AMP
5 AMP
5 AMP