INSTRUCTION MANUAL

KUSSMAUL ELECTRONICS CO., INC

.

170 CHERRY AVE., WEST SAYVILLE, N.Y. 11796

FILE: 091-120-XX-XX-(XXX)(XX).P65

Date 09-24-00

TEL: in NY 631-567-0314                   TOLL FREE: 800-346-0857                FAX: 631-567-5826

AUTO CHARGE

3 STEP

AUTOMATIC BATTERY CHARGER

3 YEAR WARRANTY

MODEL #091-120-XX-XX-(XXX)(XX)

R

Summary of Contents for 091-120

Page 1: ...CO INC 170 CHERRY AVE WEST SAYVILLE N Y 11796 FILE 091 120 XX XX XXX XX P65 Date 09 24 00 TEL in NY 631 567 0314 TOLL FREE 800 346 0857 FAX 631 567 5826 AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER 3 YEAR WARRANTY MODEL 091 120 XX XX XXX XX R ...

Page 2: ...HARGER FEATURES Completely automatic operation charges battery on demand Output Voltage regulated eliminates overcharging battery Output Voltage temperature compensated optional Output current limited to protect charger from overloading A 5 LED display indicating charge state and faults Reverse polarity protection INSTALLATION The 3 STEP CHARGER should be installed in an area with adequate ventila...

Page 3: ...ge during float charge and the green indicator labeled Battery Charged is illuminated Figure 1 depicts the above described operation Note that the term absorption charge is used interchangeably with finish charge Upon application of AC power the charger is placed into bulk charge When the charger switches to finish charge a timer starts In the event that the charge current did not taper down to ap...

Page 4: ...GE FLOAT STAGE ABSORPTION STAGE Voltage Increasing Current Constant Voltage Constant Current Decreasing Voltage Constant Full Charge Maintained STAGE I CONSTANT CURRENT BULK STAGE II CONSTANT VOLTAGE ABSORPTION STAGE III CONSTANT VOLTAGE FLOAT TIME Figure 1 ...

Page 5: ...GE FINISH CHARGE BATTERY CHARGED BAT 2 1 TEMP SENSE OUTPUT L N INPUT CHARGING WIRE SIZE VOLTS AWG 12 24 32 36 48 72 96 120 10 12 12 14 16 16 16 16 THERMISTOR OPTIONAL BATTERY BLACK GREEN WHITE A C INPUT POWER Figure 2 INSTALLATION WIRING ...

Page 6: ...hours 091 128 72 4 115 Volts 60 Hz 6 Amps 8 amp Slow Blow 72 Volts 4 Amps 8 Ampere 13 to 26 ampere hours 091 128 96 3 115 Volts 60 Hz 6 Amps 8 amp Slow Blow 96 Volts 3 Amps 4 Ampere 10 to 20 ampere hours 091 128 120 2 115 Volts 60 Hz 6 Amps 8 amp Slow Blow 120 Volts 2 Amps 4 Ampere 7 5 to 15 ampere hours 091 120 12 20 230 230 Volts 60 Hz 3 Amps 5 amp Slow Blow 12 Volts 20 Amps 25 Ampere 75 to 150 ...

Page 7: ......

Page 8: ...y material or defects which become apparent in normal use within 3 years from the date the equipment was shipped Kussmaul Electronics Company Inc shall have no liability for dam ages of any kind to associated equipment arising from the installation and or use of the Kussmaul Electronics Company Inc products The pur chaser by the acceptance of the equipment assumes all liability for any damages whi...