15 FUNCTIONS 34 RANGES

Model  KM 2783

3¾ DIGIT 1000A AC DUAL  DISPLAY

 DIGITAL CLAMP METER

SAFETY :

?

  

Safety Standards :

 The meter is up to the  standards of IEC 1010 double insulation,  Pollution Degree 2, Overvoltage CAT II

GENERAL SPECIFICATIONS :

ACCESSORIES :

 

Battery, Manual, Test leads(1 pair), Carrying Case.

-  +

ï

  Sensing :

 Average sensing.

ï

  Jaw opening size :

 45 mm

ï

  Display  :

 3¾ digit LCD with a max. Reading of 3999.

ï

  Range Selection :

 Autorange selection

ï

  Polarity :

 Automatic negative polarity indication

ï

  Zero adjustment :

 Automatic

ï

  Over range indication :

 only the “OL” display

ï

  Low battery indication :

 The “          ” is display when the battery Voltage is below 7.2V.

ï

  Auto Power Off :

 30 minutes after stopping the switch or no push button, the meter automatically  enter to

                                   power off mode.  Push button or run switch, auto power off disable.

ï

  Operating Temperature :

 0 ~ 40°C, Humidity < 80% R.H.

ï

  Storage Temperature :

  -20 ~ 60°C, Humidity < 90% R.H.

ï

  Power Supply : 

9V zinc ~ carbon battery.

ï

  Dimension :

 225(H) x 77(W) x 45(D) mm

ï

  Weight :

 approx. 330g. (Including battery)

ELECTRICAL  SPECIFICATIONS  - KM 2783

Accuracies are ±(% of r digit) at 23°C ± 5°C Less than 70% R.H.

AC VOLTAGE 

Average sensing, calibrated to rms of sine wave 

Overload  protection :

 1000V DC /750Vrms AC; 

Impedance :

 10M

W

, More then 100M

W

 on 400mV scale

Range 

Resolution 

Accuracy 

400  mV

4         V

40       V

400     V

750     V

0.1  mV

1     mV

10   mV

100 mV

1        V

±(3.0%rdg + 15dgts)

±(2.5%rdg + 15dgts)

±(1.0%rdg + 15dgts)

Frequency 

50~100Hz 

50~400Hz 

Overload protection :

 250V DC/250Vrms AC

Sensitivity : 

Range of input voltage : 1.5V~1 0V, 

                     if input voltage over range,
                     need adjust

FREQUENCY 

Accuracy 

Resolution 

Range 

10       Hz

100     Hz

1000  Hz

10     kHz

100   kHz

1000 kHz

10    MHz

10   kHz

1     kHz

100   Hz

10     Hz

1       Hz

0.1    Hz

0.01 Hz

±(0.5%rdg + 15dgts)

Built-in buzzer sounds
if reisitance is less 
than 90

W

Overload protection :

 250V DC/250Vrms AC

DIODE AND AUDIBLE CONTINUITY TEST

Range 

Description 

Test condition 

Display read approx. 
Forward voltage of 
diode.

Forward DC current 
approx. 0.4mA
Reversed DC Voltage 
Approx. 1.5V

Open circuit voltage 
approx. 0.5V

CAPACITANCE 

Overload protection :

 250V DC/250Vrms AC

Range 

Resolution 

Accuracy 

40    nF

400  nF

4      

m

F

40    

m

F

100  

m

F

10    pF

100  pF

1      nF

10    nF

100  nF

±(3.5%rdg + 30dgts)

±(2.5%rdg + 25dgts)

±(5.0%rdg + 20dgts)

RESISTANCE 

Overload protection :

 250V DC/250Vrms AC

0.1   

W

1      

W

10    

W

100  

W

1    k

W

10  k

W

Accuracy 

Resolution 

Range 

±(2.0%rdg + 20dgts)

±(1.2%rdg + 20dgts)

±(1.8%rdg + 20dgts)

400    

W

4      k

W

40    k

W

400  k

W

4     M

W

40  M

W

DC VOLTAGE 

Overload protection :

 1000V DC/750Vrms AC

Impedance :

 10M

W

 , More then 100M

W

 on 

                      400mV scale

400  mV

4         V

40       V

400     V

1000   V

0.1  mV

1     mV

10   mV

100 mV

1        V

±(0.5%rdg + 7dgts)

±(0.8%rdg + 7dgts)

Range 

Resolution 

Accuracy 

50~60Hz 

50~60Hz 

AC CURRENT

Average sensing, calibrated to rms of sine wave 

Overload  protection :

 1000Arms within 60 seconds.

Range 

Resolution 

Accuracy 

40       A

400     A

1000   A

0.01   A

0.1     A

1        A

±(2.5%rdg + 25dgts)

±(5.5%rdg + 25dgts)

±(2.5%rdg + 25dgts)

Frequency 

0~800

800~1000

±(2.0%rdg + 20dgts)

DUTY CYCLE

0.1% ~99.9%

Preliminary Data

Summary of Contents for KM 2783

Page 1: ...Overload protection 1000V DC 750Vrms AC Impedance 10MW More then 100MW on 400mV scale Range Resolution Accuracy 400 mV 4 V 40 V 400 V 750 V 0 1 mV 1 mV 10 mV 100 mV 1 V 3 0 rdg 15dgts 2 5 rdg 15dgts 1...

Page 2: ...Fax 022 24149659 Email kusam_meco vsnl net Website www kusamelectrical com www kusam meco co in OFF Hz V W CAP C 40A OFF AUTO POWER OFF DH 2sec SELECT RANGE REL HzDuty A AUTO 999 9 COM T T VW Hz CAT I...

Page 3: ...ure current in excess of your meter s capacity Check the current capacity of the Clamp meter If you are measuring current in industrial environment to prevent excess current from flowing through your...

Page 4: ...e care should be taken when using the instrument to conjunction with a current transformer connected to the terminals if an open circuit occurs 7 Ensure that the test leads and probes are in good cond...

Page 5: ...225 H x 90 W x 45 D mm Weight Approx 330g including batteries 03 04 3 ELECTRICAL SPECIFICATIONS Accuracies are of reading number in last digits at 23 5 C 75 RH DC Voltage AC Current Average sensing ca...

Page 6: ...oltage is over range need adjust 06 Range 10 Hz 100 Hz 1000 Hz 10 kHz 100 kHz 1000 kHz 10 MHz Resolution 0 01 Hz 0 1 Hz 1 Hz 10 Hz 100 Hz 1 kHz 10 kHz Accuracy 0 5 rdg 15 dgts Diode and Audible Contin...

Page 7: ...e will be smaller and the auto range mode will changed to manual range mode 6 REL key Press the key the present display value will be stored in memory then the new display value is the difference betw...

Page 8: ...ce measurement 1 Connect the black test lead to COM socket and red test lead to the socket 2 Set the selector switch to desired O position the present function is resistance measurement if it is other...

Page 9: ...he resistance is less than approx 50 Audible Continuity test Temperature measurement 1 Connect the black test lead of the sensor to COM socket and the red test lead to the socket 2 Set the selector sw...

Page 10: ...l get more accurate test result 5 Keep the multimeter away from dust and dirt which can cause premature wear of parts 4 CARE AND MAINTENANCE 1 Caring For Your Multimeter KM 2783 Digital Multimeter is...

Page 11: ...to end user customers only but have no authority to extend a greater or different warranty on behalf of KUSAM MECO KUSAM MECO s warranty obligation is limited at option free of charge repair or replac...

Reviews: