Display Mode Options
Option 27 — WGF Vapor Correction Factor
To
view
the
Vapor
Correction
Factor
information
in
Display
mode:
1>
Press
D
.
2>
Press
2
to
invoke
the
Quick
Jump
option.
3>
Press
27
for
the
WGF
Parameters
menu,
and
then
press
E
.
WGF CORRECTION
>ENABLED
This
determines
if
the
correction
for
condensing
gas
is
turned
on
or
off.
4>
Press
P
to
continue.
PROCESS TMAX
>100.00000000 DEGF
The
Process
TMAX
is
the
estimated
maximum
saturation
temperature
in
the
pipe.
For
a
digester
application,
this
will
match
the
digester
temperature
(a
typical
digester
operates
at
100°F).
If
this
value
is
set
too
high,
it
will
overcorrect
the
wet
‐
to
‐
dry
flow
rate.
The
unit
of
measurement
is
either
Celsius
or
Fahrenheit.
If
the
TMAX
value
is
set
to
zero
(0.0),
the
flow
meter
will
output
the
condensing
gas
flow
rate,
effectively
disabling
the
correction.
5>
Press
P
to
continue.
PROCESS PRESSURE
>14.7000000 PSI
The
Process
Pressure
is
the
pressure
in
the
line
where
the
flow
is
being
measured.
The
unit
of
measurement
is
either
kPA
or
PSI.
6>
Press
H
to
exit.
The
main
Display
mode
(DSP)
prompt
appears.
^
^
Summary of Contents for 410FTB
Page 1: ...Operations Guide for B Series Flow Meters 368042E...
Page 4: ...Kurz B Series Operations Guide iv...
Page 9: ...Kurz B Series Operations Guide ix Preface...
Page 33: ...Kurz B Series Operations Guide 1 20 B Series Flow Meter Modes Menus...
Page 65: ...Kurz B Series Operations Guide 2 32 B Series Flow Meter Display Mode Options...
Page 141: ...Kurz B Series Operations Guide 4 68 Program Mode Advanced Setup...