28
3BA00205 • 2020-10-28 • Rev. 5
Ersa i-CON
VARIO 2
Functional description
6.3.1
i‑SET TOOL
The i‑SET TOOL (optional) enables you to save the settings (including the password) of the station in
the i‑SET TOOL and to write it back to the station. This way you can quickly transfer the basic settings
to several stations. For more details please refer to the operating instructions for the i‑SET TOOL.
This is how you can use the i-SET TOOL:
■
Disconnect the soldering tool from the tool socket and connect the
i-SET TOOL with this socket
■
Turn the i-OP and select the following:
Upload: The data from the station is written into the i‑SET TOOL.
Download: Data from the i‑SET TOOL is written into the station. Then
press the i-OP.
A safety dialog appears:
■
Select [Cancel] to quit the process or [>>>] to continue.
■
Press the i‑OP, the settings will be saved. Wait until the text
[Parameter saved] appears in the display. Then remove the
i-SET TOOL.
Display contrast, calibration and offset are not transferred. The transfer of data solely
takes place via the tool sockets A1 of the i-CON VARIO 2. When transferring data to
the soldering station, the parameters for all soldering tools will be overwritten. Please
remember this when operating different tools on your soldering station.
6.3.2
Target temperature
The target temperature is the enabled soldering tool’s temperature pre-
set for working.
The tool’s temperature can be changed directly in operating mode by turning i OP.
Then press i‑OP to confirm it.