26
3BA00205 • 2020-10-28 • Rev. 5
Ersa i-CON
VARIO 2
Functional description
6.2.9
Working with the heating plate
The heating plate is switched on as follows:
■
With the function [Heating plate] activated, you can switch on the
heating plate in the working mode by double‑clicking the i‑OP.
■
The window
①
appears for 2 seconds. The symbol
②
signalizes that
the heating plate is working. Display
③
indicates the set heating
range.
The heating plate is switched off as follows:
■
Double‑click the i‑OP to switch off the active heating plate.
In working mode the heating range is changed as follows:
■
Double‑click the i‑OP to switch on the heating plate.
The window
①
appears.
■
Press the i‑OP again. Select the desired heating range by turning the i‑OP.
■
Press the i‑OP again to accept the set value. The heating plate now operates with
the set heating range.
Once the soldering station changes to idle state, the heating plate is also switched off.
The fact of the soldering station being taken out of the idle state does not automatically
switch on the heating plate. You have to manually switch it on by double‑clicking the
i‑OP. Read more about this in chapter 6.4.9 [Adjustable shut‑down function (idle state)].
6.2.9.1
Power values of the heating plate
The maximum temperature has been limited to 300 °C
(Heating stage 6) to prevent overheating of the heating
plate.
The following characteristic shows the end temperatures
of the heating plate at the various heating ranges.
•
Horizontal (x): Set heating range
•
Vertical (T): Temperature after 10 minutes of heating
70
20
120
170
220
270
320
2
3
1
4
5
6
x
T
(°C)