6 | Function description
Temporarily editing the soldering profile in the [Rework] tab
6.5.4 The chart in the [Rework] tabulator
When selecting tab [Rework], chart (4) with the heating curves will be displayed in
the middle of the screen and, below, the button row for the [Process automation ]
(6). The heating curves and the button for [Process automationcan be changed
here.
For all changes made in tab [Rework], the following applies: changes are accepted
but cannot be saved. If you switch from tab [Rework] to another tab, all changes
will be lost.
Rework
Archive
User administration
Profile management
Administration
Manual Mode
Soldering
Desoldering
Name
Placement
Profile settings
Search
Heater config
Information
Board
Component
Control sensor
Adaptor (head)
Pin 1 orientation
Dip mode
Placement mode
Drop height
TC1
Distance 50 mm
No orientation
No automation
Placement
Heating head position
Placement
Inspection
Soldering
Inspection
Desoldering
Soldering
Desoldering
Synchronize
Process automation
Combined
Nozzle
START/REFERENCE
Component filter
The following buttons are available:
– [Soldering]: The soldering blue heating curve is highlighted in the chart. Then
the heating curve for soldering may be changed. Functions can be set in tab
[Heater config] for soldering.
– [Desoldering]: The desoldering heating curve is highlighted in green in the
chart. Then the heating curve for desoldering may be changed. Functions can
be set in tab [Heater config] for desoldering.
– [Combined]: The heating curves of the soldering and desoldering temperature
are highlighted in the chart. The complete soldering process is displayed. The
heating curves cannot be changed and tab [Heater config] is locked. If you want
to change the heating settings specified in the soldering profile, deselect but-
ton [Combined] and instead select buttons [Soldering] or [Desoldering].
– [Synchronize]: changes the desoldering heating curve to the soldering one.
Both heating curves will be congruent. In this status, any changes in the chart
and functions in the tab [Heater config] will affect soldering and desoldering.
For the temperature values of the thermocouples, the left Y-scale of the chart with
the temperature values applies. For correcting variables (e.g. TC infrared coil, Outer
IR emitter) the right Y scale in the chart indicating maximum values of 100% ap-
plies.
Ersa GmbH
Operating_instructions HR 500 DE 3BA00246-01 | Rev. 1
65 / 124