background image

15

GB

RECOMMENDATIONS AND SUGGESTIONS

INSTALLATION

• The manufacturer will not be held liable for any damages resulting

from incorrect or improper installation.

• The minimum safety distance between the cooker top and the

extractor hood is 650 mm.

• Check that the mains voltage corresponds to that indicated on the

rating plate fixed to the inside of the hood.

• For Class I appliances, check that the domestic power supply

guarantees adequate earthing.
Connect the extractor to the exhaust flue through a pipe of minimum
diameter 120 mm. The route of the flue must be as short as possible.

• Do not connect the extractor hood to exhaust ducts carrying

combustion fumes (boilers, fireplaces, etc.).

• If the extractor is used in conjunction with non-electrical appliances

(e.g. gas burning appliances), a sufficient degree of aeration must
be guaranteed in the room in order to prevent the backflow of exhaust
gas. The kitchen must have an opening communicating directly with
the open air in order to guarantee the entry of clean air.

USE

• The extractor hood has been designed exclusively for domestic use

to eliminate kitchen smells.

• Never use the hood for purposes other than for which it has ben

designed.

• Never leave high naked flames under the hood when it is in operation.
• Adjust the flame intensity to direct it onto the bottom of the pan only,

making sure that it does not engulf the sides.

• Deep fat fryers must be continuously monitored during use:

overheated oil can burst into flames.

• The hood should not be used by children or persons not instructed in

its correct use.

MAINTENANCE

• Switch off or unplug the appliance from the mains supply before

carrying out any maintenance work.

• Clean and/or replace the Filters after the specified time period.
• Clean the hood using a damp cloth and a neutral liquid detergent.

650 mm min.

Summary of Contents for KD 6200

Page 1: ...Bedienungsanleitung Instructions Booklet Mode d emploi Libretto Istruzioni Gebruiksaanwijzing Manual de instrucciones NL IT FR GB DE KD 9650 0 E ES ...

Page 2: ...recommendations contained in this Instruction Manual your appliance will give you constant high per formance and will remain efficient for many years to come RECOMMENDATIONS AND SUGGESTIONS 15 CHARACTERISTICS 16 INSTALLATION 17 USE 20 MAINTENANCE 21 ...

Page 3: ...ent degree of aeration must beguaranteedintheroominordertopreventthebackflowofexhaust gas The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air USE The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells Never use the hood for purposes other than for which it has ben designed Neverleavehighnakedf...

Page 4: ... 2 2 1 Lower Section 8 1 DirectionalAirOutletgrille 9 1 Reducer Flange ø 150 120 mm 10 1 Flange ø 150 mm Ref Q ty Installation Components 7 2 1 2 Upper Chimney Section Fixing Brackets 7 4 1 AirOutletConnection 11 8 WallPlugs 12a 8 Screws 4 2 x 44 4 12c 6 Screws 2 9 x 6 5 13 1 Gasket Q ty Documentation 1 InstructionManual 2 1 2 2 2 1 11 12a 12c 12a 7 2 1 11 9 10 7 4 13 ...

Page 5: ...ll as shown at X mm below the first bracket X height of the upper chimney section supplied aligning the centre notch with the vertical line Mark the wall at the centres of the holes in the bracket Mark a reference point as indicated at 116 mm from the vertical reference line and 335 mm above the horizontal reference line Repeat this operation on the other side Drill ø 8 mm holes at all the centre ...

Page 6: ...ixthepipeinpositionusingsufficientpipeclamps not supplied Remove any activated charcoal filters RECIRCULATION VERSION AIR OUTLET Lean the air outlet junction 7 4 against the wall and place it under the upper fixing bracket 7 2 1 centring it to the vertical reference line Mark the centre of the fixing slots Drill ø 8 the marked points Put the dowels 11 into the holes Fix the flange 10 to the lower ...

Page 7: ...pper exhaust flue Slightly widen the two sides of the upper flue andhook them behind the brackets 7 2 1 making sure that they are well seated Secure the sides to the brackets using the 4 screws 12c 2 9 x 9 5 supplied Lower exhaust flue Open the two side flaps of the Chimney stack slightly hook them between the upper Chimney stack and the wall and close them again until they fit into place fastenin...

Page 8: ...ration It can be disabled by pressing the button T4 Flashing POWER function maximum suction power Press T4 for approximately 3 seconds to enable the Power function maximum suction power which is indicated by flashing of the LED This function will be revert to intensive speed after 5 minutes or when T4 is pressed again S1 Led Fixed SignalstriggeringoftheMetalGreaseFilterssaturationalarm indicating ...

Page 9: ... the Comfort Panel using the knobs provided Disconnect the panel from the hood canopy by sliding the fixing pin lever The comfort panel must never be washed in a dishwasher Cleantheoutsideusingadampclothandneutral liquid detergent Clean the inside as well using a damp cloth and neutral detergent do not use wet cloths or sponges or jets of water do not use abrasive substances When the above operati...

Page 10: ...lour after a time but this has absolutely no effect on its efficiency When refitting the filters make sure that the handle is visible on the outside Close the comfort panel Activated charcoal filter Recirculation version The filter is not washable and cannot be regenerated It must be replaced when led S1 flashes or at least every 4 months The alarm signal will only light up when the extractor moto...

Page 11: ... lighting unit by turning the knob provided Remove the saturated activated carbon filter by releasing the fixing hooks Fit the new filter by hooking it into its seating Replace the lighting unit Lighting LIGHT REPLACEMENT 20 W halogen light Extract the lamp from the lamp holder by pulling gently Replace with another of the same type making sure that the two pins are properly inserted in the lamp h...

Reviews: