background image

15

GB

650 mm min.

RECOMMENDATIONS AND SUGGESTIONS

INSTALLATION

• The manufacturer will not be held liable for any damages resulting

from incorrect or improper installation.

• The minimum safety distance between the cooker top and the

extractor hood is 650 mm.

• Check that the mains voltage corresponds to that indicated on the

rating plate fixed to the inside of the hood.

• For Class I appliances, check that the domestic power supply

guarantees adequate earthing.
Connect the extractor to the exhaust flue through a pipe of
minimum diameter 120 mm. The route of the flue must be as short
as possible.

• Do not connect the extractor hood to exhaust ducts carrying

combustion fumes (boilers, fireplaces, etc.).

• If the extractor is used in conjunction with non-electrical appliances

(e.g. gas burning appliances), a sufficient degree of aeration must
be guaranteed in the room in order to prevent the backflow of
exhaust gas. The kitchen must have an opening communicating
directly with the open air in order to guarantee the entry of clean
air.

USE

• The extractor hood has been designed exclusively for domestic

use to eliminate kitchen smells.

• Never use the hood for purposes other than for which it has ben

designed.

• Never leave high naked flames under the hood when it is in

operation.

• Adjust the flame intensity to direct it onto the bottom of the pan

only, making sure that it does not engulf the sides.

• Deep fat fryers must be continuously monitored during use:

overheated oil can burst into flames.

• The hood should not be used by children or persons not instructed

in its correct use.

MAINTENANCE

• Switch off or unplug the appliance from the mains supply before

carrying out any maintenance work.

• Clean and/or replace the Filters after the specified time period.
• Clean the hood using a damp cloth and a neutral liquid detergent.

Summary of Contents for EKD 10650

Page 1: ...650 EKD 10650 EKD 10650 EKD 10650 EKD 10650 Bedienungsanleitung Instructions Booklet Mode d emploi Libretto Istruzioni Gebruiksaanwijzing Manual de instrucciones Manual de instru es NL IT FR GB DE ES...

Page 2: ...ecommendations contained in this Instruction Manual your appliance will give you constant high performance and will remain efficient for many years to come RECOMMENDATIONS AND SUGGESTIONS 15 CHARACTER...

Page 3: ...t degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas The kitchen must have an opening communicating directly with the open air in order to guarantee the...

Page 4: ...16 GB CHARACTERISTICS Dimensions 650 min 400 905 582 962 1 0 0 0 740 68 min 820 310 78 max 1140 493 1414 122...

Page 5: ...mprising 2 1 1 Upper Section 2 2 1 Lower Section 9 1 Reducer Flange 150 120 mm 14 1 2 Air Outlet Connection Extension 15 1 Air Outlet Connection Ref Q ty Installation Components 7 1 1 Hood Connector S...

Page 6: ...the centres of the holes in the bracket Place the Hood Connector Support 7 1 7 1 7 1 7 1 7 1 on the wall as shown at 357 mm above the horizontal reference line making sure that the holes used to fix t...

Page 7: ...a 120 mm air exhaust connection insert the reducer flange 9 9 9 9 9 on the hood body outlet Fix the pipe in position using sufficient pipe clamps not supplied Remove any activated charcoal filters REC...

Page 8: ...d the brackets 7 2 1 7 2 1 7 2 1 7 2 1 7 2 1 making sure that they are well seated Secure the sides to the brackets using the 4 screws 12e 12e 12e 12e 12e 2 9 x 9 5 supplied Lower exhaust flue Lower e...

Page 9: ...M M Motor Switches the extractor motor on and off at low speed Used to provide a contin uos and silent air change in the presence of light cooking vapours V1 V1 V1 V1 V1 Speed Reduces the operating s...

Page 10: ...ng the filters Cleaning the filters Cleaning the filters Cleaning the filters Cleaning the filters The filters are washable and must be cleaned when led S1 S1 S1 S1 S1 flashes or at least every 2 mont...

Page 11: ...metal grease filters Alarm signal activation Alarm signal activation Alarm signal activation Alarm signal activation Alarm signal activation On the recirulcation version extractor hood the filter satu...

Reviews: