H2-50-02
25
For internal use only
10. Cooking zone valve measuring voltage
Applied voltage (average value) for the respective type of gas:
Master valve
Supply voltage 24V DC
Natural gas
Liquid gas
1
11.7 V
10.5 V-DC
2
12.1 V
10.9 V-DC
3
12.5 V
11.3 V-DC
4
12.9 V
11.7 V-DC
5
13.5 V
12.2 V-DC
6
14.1 V
12.8 V-DC
7
14.9 V
13.5 V-DC
8
15.6 V
14.3 V-DC
9
16.4 V
15 V-DC