H2-50-02
23
For internal use only
8.
Fault messages
The electronic circuit boards constantly check on their own status. If any problems with the hardware or
defections of the circuit board occur which could have a negative effect on the safety of the end user,
the appliance will switch to a “safe” status in which the electric valves are switched off. The code for the
type of error appears in the display.
It is only possible to reset the electronic system by disconnecting the power supply for at least 30 minutes
or by turning the mains plug by 180 degrees. If this does not delete the error message, the electronic
unit will have to be replaced.
Table 4:
Type of fault
Error code
displayed
Individual cooking zone burner blocked
B
Extra flames/ fault in the flame detection electric circuit for
individual cooking zone burners
F
Master valve electric circuit fault
Flt00
Electric circuit reference voltage fault
Flt01
Watchdog circuit fault
Flt02
Microcontroller port fault
Flt03
Eeprom fault
Flt04
Valve control circuit fault
Flt05
Exceeding of the maximum of 5 unlocking processes in
15 minutes
Flt06
Supply electric circuit fault
Flt08
Resonator fault/general fault
Flt09
Cooking zone burners all blocked
Flt0A
Communication error in the control logic
Flt0[
Keyboard control error
Flt0E