19
Service Manual
For internal use only
Door alignment
The door must be parallel and flush with the
control panel. The clearance between the door
and the control panel must be approx. 7 mm.
In order to avoid alignment problems as a result of
transporting the appliance, the door is fastened to
the casing with adhesive tape to protect the
appliance from strong vibrations.
The door can also be aligned when it has been
mounted. The hinged door holder (spare-part no.
528895) must be released in order to relieve the
door tension. The door will then need to be adjus-
ted so that the clearance between the door and
the control panel is 7 mm. The screws are then
tightened again.
6.4
Control panel
1. Remove the four fastening screws.
2. Loosen the four clips on the lower edge first and then those on the top edge.
3. Now carefully pull out the control panel, paying close attention to the cables and the electronic
components.
Caution!
Be particularly careful with the inner frame after the control panel has been
removed, since it may break.
7 mm
hinged door holder
Screws