    Krypton Multi Installation and Set Up Guide 

 

Kuntze Instruments 

 

 

3316 Leechburg Road | Lower Burrell | Pennsylvania | 15068 
724-339-8510 | [email protected] | www.kuntzeinstruments.com 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cleaning Sensors 

IMPORTANT

: Sensors must be cleaned by hand before being 

inserted into their respective chamber!  

1.  How to clean pH sensor:  

- Remove sensor from assembly and cable 
- Wipe off any pollution with paper tissue, rinse with water 

NEVER use abrasive substances on glass bulb! 

- Use mild acid (dilute HCl) to remove stains, use alcohol to     
   remove fats 
- Rinse with water and reinstall

 

2.  How to clean DIS sensor: 

- Remove sensor from assembly and cable 
- Wipe off any pollution with paper tissue, rinse with water 
- Clean metal bands with powder detergent (ex. Comet), wipe  
   gently 
- Rinse with water and reinstall 
 

Calibrating Sensors 

pH Sensor 

1.  Menu > Cal > Cal pH 
2.  Calibrate sensor with pH 7 buffer solution followed by pH 

4 buffer solution 

3.  Save results 

DIS Sensor 

1. 

IMPORTANT: Clean sensor before proceeding with 
calibration! 

2.  Using water sample taken from Sampling Reference 

Valve, perform DPD test 

3.  Menu > Cal > Cal DIS > enter DPD reference value > Ok 

> Save 

Inserting Sensors  

1.  Insert pH sensor into the Flow Cell Chamber for the pH 

Sensor (7) and screw on the pH cable 

2.  Insert Disinfection sensor into the Flow Cell Chamber for 

the Disinfection Sensor (9) and screw on the Disinfection 
Cable 

 

Check Your Flow 

Make sure the Water Sampling Reference Valve is in the closed 
position.  

System needs proper flow to operate. “Digital input 1 – no 
water” will show on display screen if flow is not strong enough. 

 
Flow minimum: 5 psi 

Flow maximum: 87 psi 

General Steps 

1.  Mount the system upright on the wall 

2. 

Insert clean sensors 

3.  Power on system 

4. 

Check flow 

5. 

Calibrate sensors 

6.  If needed, set user specific settings 

– 

see operations manual 

a.  ASR 

b.  4 

– 20 mA 

c. 

Relay Alarms  

IMPORTANT

: Secure lock pin after opening and 

closing your system to protect from water 

damage!

 

 

 

Power Requirements 

System comes with US power cord 

Line Voltage

85-265 V AC, 50-60 Hz 

Power Consumption

10 VA 

 

 

 

 

***Picture depicts system with three chambers.  

                                 

 

Key

 

1

 

– Neon Multi Instrument 

2

 

– Lock Pin 

3

 

– Argon Stabiflow  

4

 

– FTG Temperature Cable 

5

 

– Optional third measurement 

      sensor 

6

 

– pH Cable 

7

 

– Flow Cell Chamber for pH 

      Sensor 

 

8

 

– Disinfection Cable 

9

 

– Flow Cell Chamber  

     for Disinfection    
     Sensor 
 

10

 

– Water Inflow Valve 

11

 

– Water Outflow    

       Valve 

12

 

– Water Sampling    

       Reference Valve 
 

13

 

– Mounting Board

 