ORIGINAL OPERATING INSTRUCTIONS
Operating instructions
March 3, 2018
48/55
8.5
Setting of spreading density
•
Turn at the left-hand turning knob (Pos. 10) to increase/reduce the spreading
quantity of the left-hand conveyor screw (in this example 10 g/m²).
•
Turn at the right-hand turning knob (Pos. 20) to increase/reduce the spreading
quantity of the right-hand conveyor screw (in this example 12 g/m²).
•
Lock density (see Chapter
7.13 "Density locked", page 41
) in order to evenly
increase/reduce the spreading quantity of both conveyor screws by turning the
left-hand or right-hand turning knob (Pos. 10, 20).