Electrical requirements and installation requirements 

Power Requirements   

IMPORTANT 

Observe all governing codes and ordinances. The customer is responsible for: Contacting an electrician-installer. Check that 

the electrical installation is adequate and in conformance with the National Electrical Code, ANSI / NFPA 70 (latest edition *)

or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 (the latest edition **) of the CSA, and all 

codes and ordinances in your area. If codes permit and use a wire to separate the ground, it is recommended to check the 

path of the wire by an electrician. Do not put the device to land on a gas line. Consult a qualified person if you are not sure that 

the hood is properly grounded electrically. Do not install a fuse in the neutral circuit or circuit ground.   

Location of the electrical installation   

 The cable must enter the rear wall at least 20 to 1/4 "above the height of the installation base, and between 7-5/8" and 4-7/8

"from the left side of the midline.   

MPORTANT   

Keep these instructions in order to return them to the electrical inspector. The hood must be plugged directly into a 110 volt 

wall outlet.   

Before installing the hood 

1. To ensure the most efficient ventilation possible, install the pipe in a straight line or with the least elbows possible. 

CAUTION: The output of the vent pipe should give to the outside. 

2. Two people are required for installation. 

3. Supplied hardware can secure the hood to most    walls and ceilings, consult a qualified installer to ensure that the 

hardware  provided is suitable for your type of wall or cabinet. 

4.In the case of areas prone to COLD WEATHER,install a check against extra-circulation to minimize the cold air return and a   

nonmetallic thermal break to minimize conduction of outside temperature in the duct. The valve must be placed on the side of 

the cold air from the heat insulator. The insulation must be placed as close as possible to where the pipe enters the heated 

part of the house. 

5. Air booster: The building code in your area may require the use of a make-up air system if you use a ventilation system 

which leads  the movement of air exceeding a certain number of CFM. The number of ft3/min varies from one region to 

another. Consult your HVAC professional for specific requirements in your area. 

Remove the packaging. 

CAUTION

Carefully remove the cardboard, gloves to protect against sharp edges. 

FOR MORE DETAILS AND INFORMATION, PLEASE VISIT OUR WEBSITE 

WWW.KUCHT.COM

INSTALLATION GUIDE AND USER MANUAL

Summary of Contents for KRH3001U

Page 1: ...PRO IN YOUR KITCHEN RANGE HOOD www kucht com APPLICABLE MODEL KRH3001U KRH3601U KRH4801U KRH3002U KRH3602U KRH4802U KRH3003U KRH3603U KRH3004U KRH3604U INSTALLATION GUIDE AND USER MANUAL 30 36 48 CMF...

Page 2: ...should perform the installation and wiring of the electricity in accordance with all codes and all standards including fire resistance rating 4 When you use hood together with stove please do not clos...

Page 3: ...pply of the stove BE CAREFUL NOT TO BURN YOURSELF If the flames do not go out immediately LEAVE AND CALL THE FIRE DEPARTMENT 2 NEVER PICK IP A FLAMMING PAN you could hurt yourself 3 DO NOT USE WATER i...

Page 4: ...Before installing the hood 1 To ensure the most efficient ventilation possible install the pipe in a straight line or with the least elbows possible CAUTION The output of the vent pipe should give to...

Page 5: ...rvance of the instructions contained in this manual Ventilation methods The hood is equipped with a vertical transition to remove fumes outside Recommended diameter conduit model and wall chimney hood...

Page 6: ...n to check the strength of materials depending on the type of wall or ceiling Before cutting make sure there is enough clearance in the ceiling or wall for the outlet pass You can determine for yourse...

Page 7: ...onnet Too high will affect the efficiency of the hood too low stove temperature will damage some parts of the hood So the installation height requirement is the distance between the bottom of the hood...

Page 8: ...les 5 16 in the locations shown Place the fastening clips to the wall Tighten wood screws by hand in the attachments to allow hooks to expand Remove the screws Drill guide hole 5 16inch Make clamp fix...

Page 9: ...Necessary Tools FOR MORE DETAILS AND INFORMATION PLEASE VISIT OUR WEBSITE WWW KUCHT COM INSTALLATION GUIDE AND USER MANUAL...

Page 10: ...FOR MORE DETAILS AND INFORMATION PLEASE VISIT OUR WEBSITE WWW KUCHT COM INSTALLATION GUIDE AND USER MANUAL...

Page 11: ...KRH3003U FOR MORE DETAILS AND INFORMATION PLEASE VISIT OUR WEBSITE WWW KUCHT COM INSTALLATION GUIDE AND USER MANUAL...

Page 12: ...Installation dimension figure of KRH3004U as below FOR MORE DETAILS AND INFORMATION PLEASE VISIT OUR WEBSITE WWW KUCHT COM INSTALLATION GUIDE AND USER MANUAL...

Page 13: ...FOR MORE DETAILS AND INFORMATION PLEASE VISIT OUR WEBSITE WWW KUCHT COM INSTALLATION GUIDE AND USER MANUAL...

Page 14: ...te to the wall by screws see figure 5 Use double faced aluminum foil sealed joint see figure 6 Power line color black to black white to white green to green see figure 7 Oil box of the hood see figure...

Page 15: ...Figure4 Figure5 FOR MORE DETAILS AND INFORMATION PLEASE VISIT OUR WEBSITE WWW KUCHT COM INSTALLATION GUIDE AND USER MANUAL...

Page 16: ...KRH3001U KRH3002U FOR MORE DETAILS AND INFORMATION PLEASE VISIT OUR WEBSITE WWW KUCHT COM INSTALLATION GUIDE AND USER MANUAL...

Page 17: ...FOR MORE DETAILS AND INFORMATION PLEASE VISIT OUR WEBSITE WWW KUCHT COM INSTALLATION GUIDE AND USER MANUAL...

Page 18: ...inutes after power off A1 button on off control to directly started or off Open The Fan Keep your hood working during the cooking and keep vantilating Press A1 button then A3 display screen open Butto...

Page 19: ...control Remote sensor to receive infrared IR remote control signal KRH3002U operating instruction as following Function Button LED light button F1 low speed F2 medium speed F3 high speed F4 time delay...

Page 20: ...in warm water and mild soap or dish detergent Always clean in the direction of squall lines direction of the grain Always rinse well with clear water 2 or 3 times after cleaning and dry completely A h...

Page 21: ...EASE VISIT OUR WEBSITE WWW KUCHT COM WE TRANSFORM A SIMPLE KITCHEN INTO A PRO ONE THIS IS WHY WE CARE ABOUT MAKING VERY HIGH PERFORMANCE RANGES AND HOODS TO MAKE YOU FEEL LIKE A PRO AND STYLISH COOKER...

Reviews: