69
MAINTENANCE
A
If the new fuse happens to blow out within a short time,
contact your dealer for inspection and repair. Never
"jump" the fuse with wire or foil, or install a larger
capacity fuse than is recommended.
C
Protected circuit
B
Bleeding Fuel System
Air must be removed:
1. When the fuel filter or lines are removed.
2. When tank is completely empty.
3. After the machine has not been used for a long period
of time.
C
Bleeding procedure is as follows:
1. Fill the fuel tank with fuel.
2. Start the engine and run for about 30 seconds, and
then stop the engine.
B
Checking and Replacing Blade
To avoid serious injury or death:
A
Be sure to stop the engine and remove the key.
A
Blades may be sharp. When you handle blades,
wear heavy gloves or wrap end of blade with a
rag.
A
Before checking or replacing the blade, wipe grass
and mud off the top and inside of the mower.
Especially clean up the inside of the belt cover,
because otherwise the belt life will be reduced.
C
Checking the blade
The blade cutting edges should be kept sharp at all times.
1. Sharpen the cutting edges if they look like the blade
(B).
2. Replace the blades if they look like the blade (C).
C
Replacing
1. Dismounting the mower deck.
(See "DISMOUNTING THE MOWER DECK" in
"MOWER MOUNTING" section.)
Then turn it over to expose the blades.
2. To prevent the spindle from rotating while removing
the blade bolts, perform one of the following methods:
A
Wedge a block of wood between the blade and
mower housing.
A
Use a box wrench over the pulley nut.
Then, loosen the blade bolt as illustrated.
A
Use the proper metric size box or socket wrench to
tighten or loosen the blade mounting bolt.
(2) Slow blow fuse
FUSE NO.
CAPACITY
(A)
Protected circuit
(1)
20 A
Engine stop
15 A
Charge system
15 A
Main system
15 A
Aux. outlet
10 A
Control system
(20 A)
*(Work light)
(2)
Slow blow fuse
40 A
Check circuit against
wrong battery connection
*Option: The fuse must be in only when the work light is
attached.
(A) New blade
(B) Worn blade
(C) Cracked blade
Summary of Contents for ZD1011-AU
Page 15: ...SAFE OPERATION 8 7 DANGER WARNING AND CAUTION LABELS ...
Page 16: ... 9 SAFE OPERATION ...
Page 17: ...SAFE OPERATION 10 ...
Page 18: ... 11 SAFE OPERATION ...
Page 21: ...SERVICING OF MACHINE 2 1 ROPS serial number ...
Page 69: ...50 MAINTENANCE PERIODIC SERVICE CHART LABEL 1 Part No K3411 6552 5 ...