Service - 82
SK1050 Operator’s Manual
250 Hour
Check Fan Belt for Tension and
Damage
Check belt tension every 250 hours. Belt is
properly tensioned when it moves about 1/4-3/8”
(7-9 mm) when pushed at the long span. Replace
the belt when it is worn and sinks into the pulley
groove.
Adjust Tension
1. Loosen two alternator bolts (1, 2).
2. Adjust position as needed.
3. Tighten bolts.
4. Check tension.
Change Hydraulic Filter
Change hydraulic filter every 250 hours.
Check Lug Nut Torque
Check lug nut torque at 10 hours, 50 hours and
every 250 hours thereafter. Tighten to 88-95 ft•lb
(108-129 N•m) as needed.