6.1 Detailed settings of remote control valve
Each of the valves can be individually preset in detail, but only one can be set for priority flow.
(1) Remote control valve operating status indi-
cator
(2) Priority flow status indicator
(3) Automatic shut-off timer indicator
(4) Remote control valve number
(5) Previous screen resume switch
(6) Remote control valve lock/unlock switch
(7) Priority flow status on/of switch
(8) Automatic shut-off timer on/off switch
(9) Plus (+) switch
(10) Minus (-) switch
(11) Automatic shut-off timer control
(12) Discharge rate from cylinder (retract) port
control
(13) Discharge rate from cylinder (extend) port
control
1. Display the valve number (4) to be set in detail.
2. To ensure the priority flow for the valve 1, touch the left half of the priority flow status on/off switch (7). A touch on
the right half clears this setting.
Once the priority flow is ensured, the indicator (2) lights up and stays on.
3. To set the automatic shut-off timer, touch the left half of the automatic shut-off timer on/off switch (8). A touch on
the right half clears this setting.
Once the timer is ensured, the indicator (3) lights up and stays on.
4. To lock the remote control valve, touch the left half of the remote control valve lock/unlock switch (6). A touch on
the right half clears this setting.
5. Touch the switch (5), and the previous screen reappears.
Setting the oil flow rate and timer
1. To adjust the oil flow rate for the implement (remote control cylinder), use the
“Plus (+)”
switch (9) and the
“Minus
(-)”
switch (10).
Raise the percentage to increase the oil flow rate.
2. The timer may be preset up to 60 seconds.
If the timer is set to infinity (
), the remote control valve will go into continuous operation.
NOTE :
• When you have moved the remote control valve switch or lever to the “raise” or “lower” position and then
released your hand from the switch or lever, the timer gets activated. When the set time is over, the oil
flow to the implement is interrupted. After this stage, the timer can be set only with the switch or lever.
• If during an action the switch or lever is moved in the reverse direction, the timer setting is cancelled.
K-MONITOR MAIN MENU (
PREMIUM
AND
PREMIUM KVT
MODEL ONLY)
INTELLIPANEL
™
CONTROL
M7132, M7152, M7172
89
Summary of Contents for M7-132
Page 18: ...12 M7132 M7152 M7172 ...
Page 28: ...SAFE OPERATION 22 M7132 M7152 M7172 ...
Page 29: ...SAFE OPERATION M7132 M7152 M7172 23 ...
Page 30: ...SAFE OPERATION 24 M7132 M7152 M7172 ...
Page 31: ...SAFE OPERATION M7132 M7152 M7172 25 ...
Page 32: ...SAFE OPERATION 26 M7132 M7152 M7172 ...