6. Setting the remote control valve
In the following figure, the settings of all the remote control valves can be checked.
(1) Collective remote control valve lock indicator
(2) Collective remote control valve lock switch
(3) Individual remote control valve lock/unlock switch
(4) Valve operating time
(5) Discharge rate from cylinder (retract) port
(6) Discharge rate from cylinder (extend) port
(7) Valve operating status indicator
(8) Priority valve indicator
(9) Timer mode indicator
(A) The priority flow from the hydraulic pump is set for the first remote
control valve.
(B) The automatic shut-off timer of the second remote control valve is
set at ON.
(C) The preset oil flow rate to each implement (remote control cylinder)
is displayed. The third remote control cylinder remains locked,
which means that no oil is flowing.
(D) The automatic shut-off timer (time) of remote control is displayed.
(E) Valve action status indicator
Valve action status indicator
The oil flow to the implement (remote control cylinder) is indicated with the following icons:
(1) Extend
(2) Retract
(3) Blocked (neutral)
(4) Float
(5) Lock
Modifying the settings
1. If you want to modify any of the settings, touch the
“graph”
of the relevant valve.
In so doing, the
“detailed settings of remote control valve”
screen shows up.
K-MONITOR MAIN MENU (
PREMIUM
AND
PREMIUM KVT
MODEL ONLY)
INTELLIPANEL
™
CONTROL
M7132, M7152, M7172
87
Summary of Contents for M7-132
Page 18: ...12 M7132 M7152 M7172 ...
Page 28: ...SAFE OPERATION 22 M7132 M7152 M7172 ...
Page 29: ...SAFE OPERATION M7132 M7152 M7172 23 ...
Page 30: ...SAFE OPERATION 24 M7132 M7152 M7172 ...
Page 31: ...SAFE OPERATION M7132 M7152 M7172 25 ...
Page 32: ...SAFE OPERATION 26 M7132 M7152 M7172 ...