1. Indicator colour
Most indicators light up in the following 3 colours for identification.
Green indicator
This colour indicates that the operation-related control switches and levers are enabled or disabled.
Amber indicator
This colour means that the tractor’s operating condition is being monitored.
If amber indicator lights up or starts blinking, resolve the cause of the trouble as required.
Red indicator
This colour gives a warning directly linked to the possibility of injuries and/or machine troubles.
If red indicator lights up or starts blinking, immediately resolve the cause of the trouble.
K-MONITOR MAIN MENU (PREMIUM AND PREMIUM KVT MODEL
ONLY)
This chapter covers the handling and operation of the
“Main menu”
that is routinely used.
Details regarding the use of the sub-menu can be found in a different section.
(See K-MONITOR SUB-MENU (
On the panel, detailed settings of the differential lock, PTO, remote control valve and other functions can be made
and checked. Once any setting has been made, it can also be redisplayed immediately using the function buttons.
When the implement-related ISOBUS connector and the optional live view camera are connected, this panel serves
as their monitor screen.
INTELLIPANEL
™
CONTROL
INDICATORS