4. Operating procedure for regeneration inhibit mode
(1) Parked regeneration switch
(2) DPF INHIBIT switch
(3) Regeneration indicator
(4) Parked regeneration indicator
(5) Engine RPM increase indicator
(6) Engine warning indicator
Regeneration operating procedure
1. Start the engine.
2. Press the DPF inhibit switch
, and the switch lamp illuminates.
Switch lamp
“ON”
: Regeneration inhibit mode selected.
Switch lamp
“OFF”
: Auto regeneration mode selected.
3. When the parked regeneration indicator
starts flashing:
A specific amount of PM has accumulated in the DPF muffler.
Move the tractor to a safe place and activate the DPF muffler.
(See Operating procedure for parked regeneration on page 128.)
OPERATING THE ENGINE
DIESEL PARTICULATE FILTER (DPF) MUFFLER
126
M7132, M7152, M7172
Summary of Contents for M7-132
Page 18: ...12 M7132 M7152 M7172 ...
Page 28: ...SAFE OPERATION 22 M7132 M7152 M7172 ...
Page 29: ...SAFE OPERATION M7132 M7152 M7172 23 ...
Page 30: ...SAFE OPERATION 24 M7132 M7152 M7172 ...
Page 31: ...SAFE OPERATION M7132 M7152 M7172 25 ...
Page 32: ...SAFE OPERATION 26 M7132 M7152 M7172 ...